1342-2 CCTV INSTALLATIONS^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS.~~ Designer Note: See Table 1397-4 for additional information.~~ 1342-3 DYNAMIC MESSAGE SIGN INSTALLATIONS^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS.~~ Designer Note: See Table 1397-5a, 1397-5b or 1397-6 for additional information.~~ 1342-4 VEHICLE DETECTION INSTALLATIONS^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS.~~ Designer Note: See Table 1397-7 for additional information.~~ 1342-6 RAMP METERING INSTALLATIONS^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS.~~ Designer Note: See Table 1397-9 for additional information.~~ 1342-7 ITEM 809E25000: CONDUIT, MULTICELL, MISC.: 4", ITEM 809E24000: CONDUIT, MULTICELL, MISC.: 4", JACKED OR DRILLED^^ DESCRIPTION THIS CONDUIT IS INTENDED FOR THE USE IN UNDERGROUND OR ENCASED INSIDE CONCRETE BARRIER WALL SITUATIONS REQUIRING MORE THAN ONE SINGLE CONDUIT. THIS INCLUDES THE MAIN CONDUIT RACEWAY ALONG THE FREEWAY, CONNECTION FROM PULL BOXES TO THE ROADSIDE CABINETS AND FOR RUNS OF CONDUIT FOR MULTIPLE PURPOSES, E.G., AT RAMP METER INSTALLATIONS, FOR LOOP LEAD-IN CABLE, SIGNALS CABLE FOR RAMP METER DISPLAYS, SIGNAL CABLE FOR RAMPMETER SIGNING FLASHERS & ILLUMINATION AND POWER. THE CONTRACTOR SHALL PLUG ALL UNUSED CELLS WITH CONDUIT CAPS TO ASSURE AIR AND WATER INTEGRITY OF EACH INDIVIDUAL INNERDUCT. MATERIALS THE TRAFFIC SURVEILLANCE RACEWAY SHALL CONSIST OF A FACTORY-ASSEMBLED SYSTEM OF FOUR (4) INNERDUCTS ASSEMBLED WITHIN A PROTECTIVE OUTER DUCT. THE CONDUIT SHALL ADHERE TO 909.14 AND BE POLYVINYL CHLORIDE (PVC) SCHEDULE 40 OR 80, HIGH DENSITY POLYETHYLENE (HDPE), OR APPROVED EQUIVALENT. THE INNERDUCTS SHALL BE A MINIMUM OF 1.10 INCH INSIDE DIAMETER. THE OUTER DUCT SHALL BE NOMINAL 4 INCH INSIDE DIAMETER AND MAXIMUM OUTSIDE DIAMETER OF 4.8 INCH. WHERE COUPLINGS ARE NEEDED, THE COUPLING SHALL BE DESIGNED IN A MANNER TO PERMIT EASY FIELD ASSEMBLY. THE COUPLING SHALL BE MARKED OR KEYED IN A MANNER TO ENSURE THE INNERDUCTS ARE PROPERLY ALIGNED, ANY COLOR CODES ARE CONTINUED, AND THE ADJOINING SECTION IS INSERTED TO THE PROPER DEPTH IN THE BELL. ALL KEYS AND/OR MARKINGS SHALL BE VISIBLE AFTER ASSEMBLY TO ALLOW THE INSPECTION OF EACH JOINT FOR PROPER ASSEMBLY BEFORE BURIAL. THE SEALING SYSTEM SHALL BE DESIGNED TO ASSURE AIR INTEGRITY OF EACH INDIVIDUAL INNERDUCT AND WATER INTEGRITY OF THE ENTIRE SYSTEM. WHERE INNERDUCT(S) WITHIN A MULTI-CELL DUCT ARE TO REMAIN EMPTY, ONE ¼-INCH NYLON ROPE SHALL BE INSTALLED IN EACH OF THE OPEN INNERDUCTS, THE ROPE WILL REMAIN TO BE USED FOR A FUTURE CABLE INSTALLATION. ALSO, EACH INNERDUCT SHALL BE PLUGGED TO MAINTAIN THE AIR AND WATER INTEGRITY. IN ADDITION, THE OUTER DUCT SHALL BE CAPPED TO MAINTAIN THE AIR AND WATER INTEGRITY OF THE ENTIRE SYSTEM. FOR MULTI-CELL DUCT INSTALLED IN MEDIAN WALLS, ALL ROPES AND PLUGS SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT. INSTALLATION FOR PVC CONDUITS, INSTALLATION WILL BE IN 30-INCH DEEP TRENCH, EXCEPT AS NOTED ON THE PLANS. PVC CONDUITS SHALL NOT BE INSTALLED INSIDE CONCRETE BARRIER WALL. ALL PVC MULTI-CELL CONDUIT INSTALLED OUTSIDE OF THE ROADWAY IN TRENCH SHALL BE SCHEDULE 40 UNLESS DIRECTED BY THE PROJECT ENGINEER. FOR INSTALLATIONS UNDER ROADWAYS, INSTALLATION WILL BE AT LEAST 30 INCHES DEEP, JACKED OR DRILLED UNDER PAVEMENT, EXCEPT AS NOTED ON THE PLANS. ALL JOINTS WILL BE JOINED ACCORDING TO THE MANUFACTURER’S RECOMMENDATIONS, IN ORDER TO PROVIDE AN AIR-TIGHT ENCLOSURE OF THE INTERIOR DUCTS AND A WATER-TIGHT ENCLOSURE OF THE OUTER DUCT. ALL PVC MULTI-CELL CONDUIT INSTALLED UNDER THE ROADWAY SHALL BE SCHEDULE 80. FOR HDPE CONDUITS, INSTALLATION WILL BE IN 30-INCH DEEP TRENCH, DRILLED OR PLOWED TO A MINIMUM OF 30” DEEP, ENCASED INSIDE CONCRETE BARRIER WALL, OR AS NOTED ON THE PLANS. THE HDPE CONDUIT SHALL BE INSTALLED IN CONTINUOUS LENGTHS WITHOUT JOINTS OR COUPLINGS BETWEEN PULL BOXES OR JUNCTION BOXES. INSTALLATION WITHIN 6 FEET OF GUARDRAIL WILL BE AT LEAST 30 INCHES DEEP TRENCH AND ENCASED IN CONCRETE. WHEN ENTERING A PULL BOX, CONDUIT SHALL BE BROUGHT IN 3 INCHES MINIMUM AND A MAXIMUM OF 6 INCHES FROM THE EDGE OF THE PULL BOX WALL KNOCKOUT. METHOD OF MEASUREMENT THE CONDUIT WILL BE MEASURED BY THE AMOUNT OF CONDUIT IN FEET FURNISHED AND INSTALLED OF EACH TYPE SCHEDULE 40 OR 80 MEASURED FROM CENTER-TO-CENTER OF PULL BOXES, FOUNDATION, ETC., AND WILL INCLUDE ALL FITTINGS AND APPURTENANCES, JOINTS, BENDS, GROUNDS AND CONCRETE ENCASEMENT WHERE SPECIFIED. BASIS OF PAYMENT THE PAYMENT FOR THESE ITEMS WILL BE MADE FOR THE ACCEPTED LINER FOOT QUANTITIES AT THE CONTRACT BID PRICE.~~ Designer Note: ~~ 1342-8 ITEM 809E24500: CONDUIT, 4", MULTICELL, HDPE WITH 4-1" INNERDUCTS ITEM 809E24000: CONDUIT, 4", MULTICELL, HDPE, JACKED OR DRILLED^^ DESCRIPTION THIS CONDUIT IS INTENDED FOR THE USE IN UNDERGROUND OR ENCASED SITUATIONS REQUIRING MORE THAN ONE SINGLE CONDUIT. THIS INCLUDES THE MAIN CONDUIT RACEWAY ALONG THE FREEWAY, CONNECTION FROM PULL BOXES TO THE ROAD SIDE CABINETS AND FOR RUNS OF CONDUIT FOR MULTIPLE PURPOSES, E.G., AT RAMP METER INSTALLATIONS, FOR LOOP LEAD-IN CABLE, SIGNALS CABLE FOR RAMP METER DISPLAYS, SIGNAL CABLE FOR RAMP METER SIGNING FLASHERS & ILLUMINATION AND POWER. THE CONTRACTOR SHALL PLUG ALL UNUSED CELLS WITH CONDUIT CAPS TO ASSURE AIR AND WATER INTEGRITY OF EACH INDIVIDUAL INNERDUCT. MATERIALS THE TRAFFIC SURVEILLANCE RACEWAY SHALL CONSIST OF A FACTORY-ASSEMBLED SYSTEM OF (4) INNERDUCTS ASSEMBLED WITHIN A PROTECTIVE OUTER DUCT HIGH DENSITY POLYETHYLENE OR APPROVED EQUIVALENT. THE INNERDUCTS SHALL BE A MINIMUM 1 INCH INSIDE DIAMETER. THE OUTER DUCT SHALL BE NOMINAL 4 INCH INSIDE DIAMETER AND A MAXIMUM OUTSIDE DIAMETER OF 4.8 INCH. THE HDPE CONDUIT SHALL BE COILABLE ON REELS. WHERE INNERDUCT(S) WITHIN A MULTI-CELL DUCT ARE TO REMAIN EMPTY, ONE 1/4" NYLON ROPE SHALL BE INSTALLED IN EACH OF THE OPEN INNERDUCTS, THE ROPE WILL REMAIN TO BE USED FOR A FUTURE CABLE INSTALLATION. ALSO, EACH INNERDUCT SHALL BE PLUGGED TO MAINTAIN THE AIR AND WATER INTEGRITY. IN ADDITION, THE OUTER DUCT SHALL BE CAPPED TO MAINTAIN THE AIR AND WATER INTEGRITY OF THE ENTIRE SYSTEM. INSTALLATION INSTALLATION WILL BE IN 30" DEEP TRENCH, DRILLED OR PLOWED TO A MINIMUM OF 30" DEEP, ENCASED INSIDE CONCRETE BARRIER WALL OR AS NOTED ON THE PLANS. THE HDPE CONDUIT SHALL BE INSTALLED IN CONTINUOUS LENGTHS WITHOUT JOINTS OR COUPLINGS BETWEEN PULL BOXES OR JUNCTION BOXES. WHEN ENTERING A PULL BOX, CONDUIT SHALL BE BROUGHT IN 3 INCHES MINIMUM AND A MAXIMUM OF 6 INCHES FROM THE EDGE OF THE PULL BOX AND KNOCKOUT. METHOD OF MEASUREMENT THE CONDUIT WILL BE MEASURED BY THE AMOUNT OF CONDUIT IN FEET FURNISHED AND INSTALLED, MEASURED FROM CENTER- TO-CENTER OF PULL BOXES, FOUNDATION, ETC., AND WILL INCLUDE ALL FITTING AND APPURTENANCES, JOINTS, BENDS, GROUNDS, AND CONCRETE ENCASEMENT WHERE SPECIFIED. BASIS OF PAYMENT THE PAYMENT FOR THESE ITEMS WILL BE MADE FOR THE ACCEPTED LINER FOOT QUANTITIES AT THE CONTRACT BID PRICE.~~ Designer Note: ~~ 1342-9 UNDERGROUND WARNING/MARKING TAPE^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATIONS 804/904. AND CMS 725.22.~~ Designer Note: ~~ 1342-10 COMMUNICATION CABLE MARKER^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATIONS 804/904.~~ Designer Note: ~~ 1342-11 DMS & DDMS SUPPORT STRUCTURES^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS. THE CONTRACTOR SHALL FURNISH SHOP DRAWINGS TO THE PROJECT ENGINEER FOR APPROVAL. THE DRAWINGS SHALL BE STAMPED BY A PROFESSIONAL ENGINEER FROM THE MANUFACTURER. THE ITEM SHALL NOT BE RELEASED FOR CONSTRUCTION UNTIL APPROVED BY THE OFFICE OF TRAFFIC OPERATIONS.~~ Designer Note: See Table 1397-5 and Table 1397-6 for additional information.~~ 1342-12 ITS JUNCTION BOX^^ THE CONTRACTOR SHALL SUPPLY THE MEDIAN BARRIER WALL JUNCTION PULL BOXES THAT MEET THE FOLLOWING SPECIFICATIONS: SHALL BE OF TYPE POLYMER-CONCRETE SIZE: 17 INCHES (HEIGHT) X 30 INCHES (LENGTH) X DEPTH (SPECIFY) MINIMUM WALL THICKNESS: 0.5 INCH MINIMUM LID THICKNESS: 2 INCHES ANSI TIER 22 RATING WITH A MINIMUM DESIGN LOAD OF 22,000 POUNDS LID SHALL BE MARKED "TRAFFIC." BOXES SHALL HAVE A SOLID BOTTOM. USE HORIZONTAL REINFORCING STEEL MEMBERS UNDERNEATH AND ABOVE THE JUNCTION BOX TO SECURE IN PLACE AND TIE IN TO THE REST OF THE WALL REINFORCING STEEL. THE JUNCTION BOX SHALL BE ATTACHED TO THE FORM WORK TO SECURE IT IN THE APPROPRIATE POSITION IN THE WALL DURING CONCRETE PLACEMENT. SLIP FORMING IS NOT PERMITTED IN SECTIONS OF CONCRETE WALL CONTAINING JUNCTION BOXES.~~ Designer Note: Specify the junction box depth in the above note. The depth shall be the largest possible to provide appropriate cover for concrete barrier wall soundness. Typical depth is either 12, 18, or 24 inches.~~ 1342-13 UTILITIES^^ ~~ Designer Note: Include ODOT, Office of Technical Services, Traffic Monitoring section as a utility owner anytime there is pavement milling or any excavation work within the vicinity of our permanent count stations, also known as ATR's and WIM's. Please utilize Utility Note G102A1; below is our contact info: Traffic Monitoring Section ODOT, 1980 West Broad Street, Columbus, Ohio 43223 Ed Newmeyer (FIELD OPERATION) 614-204-0914 VACANT (DISTRICT 2,3, 12) ELIZABETH MURPHY (DISTRICT 5, 6, 9, 10) 614-204-0291 DARREN GERSTENSLAGER (DISTRICT 4, 11) 614-273-4783 BRYAN STANIFER (DISTRICT 1, 7, 8) 614-204-0971~~ 1342-14 PROTECTION OF TRAFFIC MONITORING EQUIPMENT^^ PRIOR TO BEGINNING ANY PAVEMENT ACTIVITIES OR ANY EXCAVATION ACTIVITIES BETWEEN [INSERT STATION OR LOG POINTS] AND [INSERT STATION OR LOG POINT] THE CONTRACTOR, THE PROJECT ENGINEER, AND A REPRESENTATIVE FROM THE OWNER WILL COORDINATE A TIME FOR THE OWNER/MAINTAINING AGENCY TO DISCONNECT THE EQUIPMENT. FOLLOWING THE DISCONNECTION BY THE OWNER, THE CONTRACTOR WILL BE ALLOWED TO PERFORM THEIR PAVEMENT ACTIVITIES, INCLUDING PAVEMENT REMOVAL. THE REMOVE LOOPS AND SENSORS BECOME THE PROPERTY OF THE CONTRACTOR. (ADD THE FOLLOWING PORTION FOR PROJECTS THAT ALSO INCLUDE EXCAVATION ACTIVITIES) DURING THE MEETING, THE OWNER/MAINTAINING AGENCY WILL IDENTIFY EQUIPMENT LOCATIONS. DO NOT DISTURB PULL BOXES, CONTROLLERS, CABINETS, POLES AND CONDUITS. ANY DAMAGE WILL BE THE RESPONSIBILITY OF THE CONTRACTION AND REPAIRS MUST BE ACCEPTED BY THE OWNER.~~ Designer Note: For use on resurfacing, minor rehabilitation, and bridge projects within 300 feet of a permanent traffic count station. Projects of special concern - Those that involve a concrete median installation - either as part of a widening that converts the grass median to concrete or a project that replaces the existing concrete median. We need to include specific details for including a median pullbox, and occasionally conduits to allow us to reinstall loops and detectors following the construction of roadway and median work. In general, we handle reinstallation of our specialized equipment via a separate contract with certified material contractors including warranty clauses. Sometimes we request certain underground work be included with major pavement rehabs and median changes as part of a pavement project. Early project coordination is key - please contact Sandra Mapel (614-644-0291, Sandra.Mapel@dot.ohio.gov) for site specific details and needs.~~ 1342-15 MAINTAINING ITS DURING CONSTRUCTION^^ THE CONTRACTOR SHALL MAINTAIN ALL PREEXISTING OR NEWLY INSTALLED PERMANENT ITS/TRAFFIC DEVICES AND INFRASTRUCTURE DURING CONSTRUCTION ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809.~~ Designer Note: This lump sum pay item and note requires the contractor to maintain all permanent devices and communication which are existing or newly installed on the project, as well as setup any temporary communications needed, and perform utility locates for ITS/Traffic devices during construction. The plan note may be used without the pay item if the project involves little to no work for maintaining ITS/Traffic devices or infrastructure. The lump sum pay item may be used when the designer thinks it's needed to compensate the contractor for their efforts, such as when a project has a reasonable amount of ITS/Traffic devices or infrastructure within its project limits which could potentially be impacted, or it's known the contractor will have considerable work or effort in order to maintain ITS/Traffic devices or infrastructure.~~ 1342-16 CCTV CONCRETE POLE WITH LOWERING UNIT, 70 FEET^^ THE CONTRACTOR SHALL FURNISH AND INSTALL THIS ITEM ACCORDING TO ODOT SUPPLEMENTAL SPECIFICATION 809, AS WELL AS ANY STANDARD CONSTRUCTION DRAWINGS NOTED ON THE PLANS. IN ADDITION, THE CONTRACTOR SHALL INCLUDE A 1/2" ISOLATION JOINT MATERIAL BETWEEN THE CONCRETE POLE AND CONCRETE WORK PAD. HE CONTRACTOR SHALL PROVIDE 1 COMPLETE LOWERING UNIT TOOL ASSEMBLY PER CAMERA FOR LOWERING CAMERAS PER SUPPLEMENTAL SPECIFICATION 809 TO ODOT AT THE END OF THE PROJECT. ODOT AND THE OFFICE OF GEOTECHNICAL ENGINEERING HAVE OBTAINED AND ANALYZED THE SOIL BORING DATA F OR THIS SITE, LOCATED AT _________, AND DETERMINED THAT THE POLE HEIGHT SHALL BE __ FT ABOVE GROUND AND THE EMBEDMENT DEPTH SHALL BE __ FT. THE CONTRACTOR SHALL FURNISH/INSTALL POLES WITH THE CORRECT LENGTH/EMBEDMENT AND ALL COUPLINGS, HANDHOLES, ETC., IN THE APPROPRIATE LOCATION ABOVE GROUND ACCORDING TO SCD ITS-12.10. THE CONTRACTOR MAY FURNISH/INSTALL LONGER OVERALL LENGTH POLES AT A DEEPER EMBEDMENT DEPTH IF IT IS MORE BENEFICIAL FOR MANUFACTURING, SHIPPING, ETC., AS LONG AS ALL ABOVE GROUND COMPONENTS MAINTAIN APPROPRIATE HEIGHT LEVEL. IF NEEDED DUE TO UNFORESEEN CIRCUMSTANCES ARISING WITH BEDROCK, ETC., AND WITH APPROVAL FROM THE ODOT PROJECT ENGINEER, THE CONTRACTOR MAY FIELD CUT AN APPROPRIATE AMOUNT FROM THE BASE OF THE CONCRETE POLE WHICH WOULD REQUIRE LESS EMBEDMENT DEPTH IN ORDER TO MAINTAIN APPROPRIATE LEVELS ABOVE GROUND. IF A POLE IS CUT, THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO NOT DAMAGE THE INTEGRITY OF THE POLE PER MANUFACTURER RECOMMENDATIONS AND ANY EXPOSED STEEL STRANDS SHALL BE COATED WITH EPOXY. THE CONTRACTOR SHALL SUBMIT ALL POLE MANUFACTURER FABRICATION DRAWING SUBMITTALS, AS WELL AS INSTALLATION PROCEDURES AND BACKFILL MATERIAL, TO THE ODOT PROJECT ENGINEER FOR ACCEPTANCE BEFORE ORDERING. PAYMENT FOR EACH POLE COMPLETE, INSTALLED, AND ACCEPTED CONCRETE POLE WITH LOWERING UNIT, SHALL BE MADE AT THE UNIT BID PRICE FOR ITEM 809, CCTV CONCRETE POLE WITH LOWERING UNIT, 70 FEET~~