442-2
POWER SUPPLY FOR TRAFFIC SIGNALS^^

ELECTRIC POWER SHALL BE OBTAINED FROM THE _______________
AT THE LOCATION INDICATED ON THE PLANS. POWER SUPPLIED
SHALL BE _____ VOLTS.~~

Designer Note:
See Sections 440-2 and 441-4.~~


442-3
SIGNAL ACTIVATION^^

PRIOR TO ACTIVATING THE NEW TRAFFIC SIGNAL TO STOP-AND-
GO MODE AND/OR REMOVING THE EXISTING TRAFFIC SIGNAL
FROM SERVICE, ALL ITEMS IN THE PROPOSED SIGNAL PLAN
SHALL BE FULLY COMPLETED, (I.E., VEHICLE DETECTION,
PEDESTRIAN SIGNAL HEADS, ETC). IF THERE ARE
CONSTRUCTABILITY ISSUES (I.E., ROADWAY WIDENING, ETC.)
THAT PREVENT THE SIGNAL FROM BEING COMPLETED PRIOR TO
ACTIVATION, IT SHALL BE BROUGHT TO THE ATTENTION OF THE
PROJECT ENGINEER AND DISTRICT TRAFFIC ENGINEER. THE
DISTRICT TRAFFIC ENGINEER WILL THEN REVIEW, APPROVE OR
REJECT PROPOSALS TO ACTIVATE THE TRAFFIC SIGNAL PRIOR
TO COMPLETION.

THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER AND
DISTRICT TRAFFIC ENGINEER AT LEAST 10 WORKING DAYS PRIOR
TO SCHEDULING THE FINAL INSPECTION OF THE SIGNAL
INSTALLATION. FINAL INSPECTION IS NOT CONSIDERED
COMPLETE UNTIL DESIGNATED DISTRICT TRAFFIC PERSONNEL
INSPECT THE TRAFFIC SIGNAL AND ISSUE WRITTEN APPROVAL.
IF ISSUES ARE FOUND DURING THE FINAL INSPECTION THAT
EFFECT THE SAFETY OF THE TRAVELING PUBLIC AND/OR THE
EFFICIENCY OF THE INTERSECTION, THE SIGNAL SHALL NOT BE
ACTIVATED ON THE PROPOSED DATE. ANY PUNCH LIST ITEMS
THAT ARE FOUND SHALL BE CORRECTED AND REINSPECTED BY
DISTRICT TRAFFIC PERSONNEL PRIOR TO FINAL ACCEPTANCE.
ODOT FORCES SHALL ONLY ASSUME DAY TO DAY MAINTENANCE
OF THE TRAFFIC SIGNAL AFTER FINAL WRITTEN ACCEPTANCE
HAS BEEN ISSUED.~~

Designer Note:
Note shall be used for all new ODOT traffic signal installations.~~


442-4
632 REMOVAL OF TRAFFIC SIGNAL INSTALLATION^^

TRAFFIC SIGNAL INSTALLATIONS, INCLUDING SIGNAL HEADS,
CABLE, MESSENGER WIRE, STRAIN POLES, CABINET,
CONTROLLER, ETC., SHALL BE REMOVED IN ACCORDANCE WITH
C&MS 632.26 AND AS INDICATED ON THE PLANS. REMOVED ITEMS
SHALL BE REUSED AS PART OF A NEW INSTALLATION ON THE
PROJECT OR STORED ON THE PROJECT FOR SALVAGE BY (NAME
OF AGENCY RECEIVING STORED ITEMS) IN ACCORDANCE WITH
THE LISTING GIVEN HEREIN.

(ITEMS TO BE REUSED)

(ITEMS TO BE STORED)

REMOVED ITEMS SHALL BE DELIVERED TO THE NEAREST ODOT
FACILITY WHOSE ADDRESS IS LISTED BELOW:

ODOT DISTRICT X, ATTN: XXXXXX XXXXX (CONTACT PHONE NUMBER)

(ADDRESS LINE 1)
(ADDRESS LINE 2)

IN THE EVENT THE ITEMS STORED ON THE PROJECT FOR
SALVAGE BY THE LOCAL AGENCY ARE NOT REMOVED, THE
CONTRACTOR SHALL, WHEN DIRECTED BY THE ENGINEER IN
WRITING, REMOVE AND DISPOSE OF THE ITEMS AT NO
ADDITIONAL COST TO THE PROJECT.~~

Designer Note:
This note shall be included on projects where existing traffic signal installations
are being removed. A listing of items to be reused and/or stored must be included.
Pull boxes to be removed shall be itemized separately and paid for under Item 625,
"Pull Box Removed".~~


442-5
632 INTERCONNECT CABLE, MISC.: (BY SIZE), WITH SUPPORT
MESSENGER, AS PER PLAN^^

THE CONTRACTOR WILL BE PERMITTED TO USE EITHER OF TWO
TYPES OF INTERCONNECT CABLE CONSTRUCTION AND
INSTALLATION UNDER THIS ITEM AS FOLLOWS:

1.  INTEGRAL MESSENGER TYPE INTERCONNECT CABLE MEETING
    THE REQUIREMENTS OF C&MS 732.19. UNDER THIS METHOD
    ANY SECTIONS OF CABLE SHOWN IN THE PLANS TO BE
    CONTAINED IN CONTROLLERS, CABINETS, POLES, CONDUITS
    OR SUPPORTED ON MESSENGER WIRE INSTALLED FOR OTHER
    PURPOSES SHALL HAVE THE SUPPORTING MESSENGER AND
    JACKET WEB NEATLY REMOVED BY THE USE OF A TOOL
    SPECIFICALLY DESIGNED AND SIZED FOR THIS PURPOSE.
    DEVIATIONS FROM THE CABLE ROUTING SHOWN IN THE PLAN,
    FOR THE SOLE PURPOSE OF REDUCING THE AMOUNT OF
    MESSENGER TO BE REMOVED, WILL NOT BE PERMITTED. THE
    CABLE SHALL BE INSTALLED WITH APPROXIMATELY ONE TWIST
    FOR EACH 15 FEET OF SPAN LENGTH.

2.  SEPARATE INTERCONNECT CABLE MEETING THE REQUIRE-
    MENTS OF C&MS 732.19 PLUS A 1/4 INCH MESSENGER WIRE
    AND LASHING MEETING THE REQUIREMENTS OF C&MS 732.18.
    UNDER THIS METHOD THE CONTRACTOR WILL INSTALL A
    SEPARATE 1/4 INCH MESSENGER TO SUPPORT THE SPANS OF
    INTERCONNECT CABLES IN ALL LOCATIONS WHERE THE PLANS
    SHOW INTERCONNECT CABLE WHICH IS NOT OTHERWISE
    SUPPORTED BY A SIGNAL MESSENGER WIRE OR OTHER
    SUITABLE SUPPORT. UTILIZATION OF EXISTING MESSENGER
    WIRE, NOT PROVIDED BY THE PROJECT OR DESIGNATED
    THEREIN AS AVAILABLE FOR USE, IS PROHIBITED. DEVIATION
    FROM THE CABLE ROUTING SHOWN IN THE PLANS, FOR THE
    PURPOSE OF REDUCING THE NEED FOR SEPARATE
    MESSENGER WIRE, WILL NOT BE PERMITTED.

IN EITHER CASE THE NUMBER OF SPLICE LOCATIONS SHALL BE
KEPT TO A MINIMUM.

MEASUREMENT WILL BE BASED UPON THE NUMBER OF FEET OF
C&MS ITEM 632, "INTERCONNECT CABLE, MISC.: (BY SIZE), WITH
SUPPORT MESSENGER, AS PER PLAN" IN PLACE IN ACCORDANCE
WITH THE METHOD DESCRIBED IN C&MS 632.29 AND NO SEPARATE
PAYMENT WILL BE PROVIDED FOR ANY SEPARATE MESSENGER
WIRE USED TO SUPPORT INTERCONNECT CABLES.~~

Designer Note:
This note may be used on projects with overhead interconnect cable, if acceptable
to the maintaining agency.~~


442-6
632 LOOP DETECTOR UNITS, BY TYPE, AS PER PLAN^^

IN ADDITION TO THE REQUIREMENTS OF C&MS ITEM 632 AND
C&MS 732.07 OR 732.08, LOOP DETECTOR UNITS SHALL HAVE
THE FOLLOWING REQUIREMENTS OR FEATURES:

    THE OUTPUT DEVICE SHALL BE A RELAY, AND ALL CONTACTS
    SHALL BE IN THE WIRING HARNESS.

    THE UNIT SHALL BE SELF-TUNING.

    THE UNIT'S ELECTRICAL CONNECTION PLUGS OR WIRING
    HARNESS SHALL ALLOW READY REPLACEMENT WITH A SINGLE
    CHANNEL AMPLIFIER AS DESCRIBED IN C&MS 732.07.

    EACH UNIT SHALL BE LABELED TO CORRESPOND TO ITS PHASE
    AND DIRECTION.

    DELAY INHIBIT SHALL BE CONNECTED ON ALL DETECTOR
    HARNESSES FOR THEIR RESPECTIVE PHASE GREENS.~~

Designer Note:
This note should be included for projects which will be maintained by Districts that
use NEMA TS-1 controller cabinets. Bid items are not used unless detector units are
installed in an existing cabinet.~~


442-7
DETECTION MAINTENANCE^^

IF VEHICLE DETECTION BECOMES UNEXPECTEDLY DISABLED,
REQUIRES MODIFICATION, OR IS SCHEDULED TO BE 
TEMPORARILY REMOVED DURING THE CONSTRUCTION PROJECT, 
THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT 
ENGINEER AND DISTRICT TRAFFIC ENGINEER. 

IF THE LOSS OF VEHICLE DETECTION IS KNOWN PRIOR TO THE 
START OF CONSTRUCTION, IT SHALL BE DISCUSSED AT THE 
PRECONSTRUCTION MEETING. AT SUCH TIME, THE DISTRICT 
TRAFFIC ENGINEER SHALL ADVISE THE PROJECT ENGINEER AND 
CONTRACTOR ON THE APPROPRIATE ACTION TO RECTIFY ANY 
LOSS OF VEHICLE DETECTION. THIS MAY INCLUDE PLACING 
THE TRAFFIC SIGNAL ON MINIMUM OR MAXIMUM RECALL, MODIFYING 
THE MINIMUM GREEN TIMES, AND REMOVING THE MALFUNCTIONING 
DETECTION FROM SERVICE. WHERE NON-INTRUSIVE DETECTION 
(I.E. VIDEO, RADAR) ALREADY EXISTS, THE CONTRACTOR SHALL 
INSURE THAT DETECTION IS OPERATING AND MAINTAINED BY 
RECONFIGURING THE DETECTION UNITS ACCORDINGLY DURING ALL 
CONSTRUCTION PHASES. THIS IS TO AVOID THE SIGNAL FROM 
MAXING OUT THE EFFECTED SIGNAL PHASE AND CREATING 
UNNECESSARY DELAYS.

LOCATIONS WHERE NON-INTRUSIVE DETECTION IS PROPOSED 
AND THE EXISTING VEHICLE DETECTION IS TO BE ABANDON, 
THE NON-INTRUSIVE VEHICLE DETECTION SHALL BE INSTALLED, 
CONFIGURED AND MADE FULLY FUNCTIONAL PRIOR TO THE 
EXISTING DETECTION BEING DISABLED. THE CONTRACTOR SHALL 
CONTINUE TO MAINTAIN AND MODIFY THE DETECTION UNTIL 
FINAL ACCEPTANCE OF THE TRAFFIC SIGNAL. THIS IS TO 
ENSURE VEHICLE DETECTION REMAINS FULLY FUNCTIONAL 
THROUGHOUT CONSTRUCTION.~~


Designer Note:
This note shall be used on all projects where a potential conflict exists that will
affect vehicle detection.~~


442-8
WORK INSPECTION^^

THE CONTRACTOR SHALL PROVIDE THE PROJECT ENGINEER AND
DISTRICT TRAFFIC ENGINEER WITH 72-HOUR NOTICE OF ANY
SIGNAL WORK TO BE PERFORMED AT THE INTERSECTION SITE(S)
SO THAT INSPECTION SERVICES CAN BE SUPPLIED.~~

Designer Note:
The note should be used on all projects where signal modifications occur, or new
signals are constructed.~~


442-9
632 LOOP DETECTOR LEAD-IN CABLE, DIRECT BURIAL^^

THIS WORK SHALL INCLUDE FURNISHING AND INSTALLING LOOP
DETECTOR LEAD-IN CABLE OF THE TYPE REQUIRED IN C&MS
732.19. INSTALLATION SHALL BE BY CABLE PLOW OR VIBRATORY
CABLE PLOW TO A MINIMUM DEPTH OF 18 INCHES. ALL ENTRIES
INTO PULL BOXES, CONDUIT SYSTEMS, FOUNDATION OR OTHER
ENCLOSURES SHALL BE FREE OF SHARP EDGES AND BE
COVERED BY INSULATED BUSHINGS. FOLLOWING INSTALLATION,
THE GROUND SURFACE SHALL BE RESTORED TO THE ORIGINAL
CONTOUR AND SURFACE CONDITION.~~

Designer Note:
This method may be considered in lieu of cable in conduit to reduce project costs.
It is applicable to long underground runs in tree lawns or grassed roadsides where
minimal interference with driveways or utilities is expected, and where disturbance
of the area due to construction is not contemplated. If the cable is to be routed
up a pole, a conduit riser (extending below ground with an insulated bushing)
should be called for and detailed.~~


442-10
632 COMBINATION SIGNAL SUPPORT, TYPE TC-81.22 AND SIGN
SUPPORT, TC- (WITH LIGHT POLE EXTENSION)^^

THIS SUPPORT SHALL CONSIST OF A TC-______ DESIGN _____
POLE WITH A TC-81.22 DESIGN _____ SIGNAL ARM AND A
TC-______ DESIGN _____ SIGN SUPPORT ARM (WITH LIGHT POLE
EXTENSION). ALL SIGNAL SUPPORT ITEMS REQUIRED BY C&MS
ITEM 632 AND ALL SIGN SUPPORT ITEMS REQUIRED BY C&MS
ITEM 630 SHALL BE INCLUDED AS PART OF THIS SUPPORT.

PAYMENT WILL BE AT THE CONTRACT UNIT PRICE AND WILL BE
FULL COMPENSATION FOR ALL LABOR, MATERIALS, TOOLS,
EQUIPMENT AND OTHER INCIDENTALS NECESSARY FOR EACH
SUPPORT FURNISHED, IN PLACE, COMPLETE AND ACCEPTED.~~

Designer Note:
This note shall be used when combination traffic signal supports and sign supports
are desired. The blanks shall be filled in with appropriate SCD numbers and
designs.~~


442-11
632 COMBINATION STRAIN POLE, TYPE TC-81.11 AND SIGN
SUPPORT, TYPE TC- (WITH LIGHT POLE EXTENSION)^^

THIS SUPPORT SHALL CONSIST OF A TC-______ DESIGN _____
POLE WITH A TC-______ DESIGN _____ SIGN SUPPORT ARM (WITH
LIGHT POLE EXTENSION). ALL SIGNAL SUPPORT ITEMS REQUIRED
BY C&MS ITEM 632 AND ALL SIGN SUPPORT ITEMS REQUIRED BY
C&MS ITEM 630 SHALL BE INCLUDED AS PART OF THIS SUPPORT.

PAYMENT WILL BE AT THE CONTRACT UNIT PRICE AND WILL
BE FULL COMPENSATION FOR ALL LABOR, MATERIALS, TOOLS,
EQUIPMENT AND OTHER INCIDENTALS NECESSARY FOR EACH
SUPPORT FURNISHED, IN PLACE, COMPLETE AND ACCEPTED.~~

Designer Note:
This note shall be used when combination traffic signal strain poles and sign
supports are desired. The blanks shall be filled in with appropriate SCD numbers
and designs. The following is a bid item example: Combination Strain Pole, Type
TC-81.11 and Sign Support, Type TC-12.31 (with Light Pole Extension).~~


442-12
STRAIN POLE AND PEDESTAL FOUNDATION ELEVATIONS^^

ELEVATIONS SHOWN IN THE PLANS FOR STRAIN POLE AND
PEDESTAL FOUNDATIONS ARE FOR COMPUTATIONAL PURPOSES
ONLY. THE ACTUAL ELEVATION OF THE FOUNDATION SHALL BE
IN ACCORDANCE WITH TRAFFIC SCD TC-21.21 PROVIDED THE
EXISTING SLOPE IS LESS THAN 6:1.

AT LOCATIONS WHERE THE EXISTING SLOPE IS 6:1 OR GREATER,
THE BURIED DEPTH OF FOUNDATION, AS SHOWN IN SCD TC-21.21
SHALL APPLY TO THE LOW SIDE OF THE SLOPE. THE TOP OF
THE FOUNDATION SHALL BE SET 2 INCHES ABOVE THE EXISTING
SURFACE ON THE HIGH SIDE OF THE SLOPE. THE ADDITIONAL
DEPTH OF FOUNDATION NECESSARY TO MEET THESE
REQUIREMENTS SHALL BE ADDED TO THE FORMED TOP.~~

Designer Note:
This note shall be used when strain pole and pedestal foundations are located in
slopes of 6:1 or greater.~~


442-15
GUARANTEE^^

THE CONTRACTOR SHALL GUARANTEE THAT THE TRAFFIC
CONTROL SYSTEM INSTALLED AS PART OF THIS CONTRACT
SHALL OPERATE SATISFACTORILY FOR A PERIOD OF _____
DAYS FOLLOWING COMPLETION OF THE 10-DAY PERFORMANCE
TEST. IN THE EVENT OF UNSATISFACTORY OPERATION, THE
CONTRACTOR SHALL CORRECT FAULTY INSTALLATIONS, MAKE
REPAIRS AND REPLACE DEFECTIVE PARTS WITH NEW PARTS OF
EQUAL OR BETTER QUALITY.

EQUIPMENT, MATERIAL AND LABOR COSTS INCURRED IN
CORRECTING AN UNSATISFACTORY OPERATION SHALL BE
BORNE BY THE CONTRACTOR.

THE GUARANTEE SHALL COVER THE FOLLOWING ITEMS OF
THE TRAFFIC CONTROL SYSTEM: CONTROLLER, CABINET,
UNINTERRUPTIBLE POWER SUPPLY, VEHICLE DETECTION
EQUIPMENT, LED LAMP UNITS, NETWORK AND COMMUNICATION/
INTERCONNECT EQUIPMENT.

CUSTOMARY MANUFACTURER'S GUARANTEES FOR THE
FOREGOING ITEMS SHALL BE TURNED OVER TO THE STATE OR
THE MAINTAINING AGENCY FOLLOWING ACCEPTANCE OF THE
EQUIPMENT.

THE COST OF GUARANTEEING THE TRAFFIC CONTROL SYSTEM
WILL BE INCIDENTAL TO AND INCLUDED IN THE CONTRACT UNIT
PRICE OF THE VARIOUS ITEMS MAKING UP THE SYSTEM.~~

Designer Note:
See Section 441-11.~~


442-16
633 ALTERNATE BID ITEM^^

633 CABINET, TYPE _____,

  (EXAMPLE OF A STANDARD BID ITEM)

633 CABINET, TYPE _____, (ACME BRAND) (ALTERNATE 1)

THE CABINET SHALL BE A MODEL XX-99 AS MANUFACTURED
BY ACME CABINET COMPANY, SANTOY, OHIO AND SHALL BE
FURNISHED WITH ALL THE DESIGN FEATURES, AUXILIARY
EQUIPMENT, ACCESSORIES, AND PREWIRED CABINET FEATURES
AS REQUIRED IN THE STANDARD BID ITEM.

PAYMENT WILL BE AT THE CONTRACT UNIT PRICE FOR EACH,
IN PLACE, ALL CONNECTIONS MADE AND WIRING COMPLETED,
TESTED AND ACCEPTED.

  (EXAMPLE OF AN ALTERNATE BID ITEM)~~

Designer Note:
See Section 441-12.~~


442-18
632 PEDESTRIAN SIGNAL HEAD (LED), (COUNTDOWN), TYPE D2,
AS PER PLAN^^

IN ADDITION TO THE REQUIREMENTS OF C&MS 632 AND 732 THE
FOLLOWING SHALL APPLY:

1.  SIGNAL HEADS AND VISORS SHALL BE CONSTRUCTED OF
    BLACK POLYCARBONATE PLASTIC AND MEET ITE
    SPECIFICATIONS.

2.  PROPER EXTERIOR COLORS SHALL BE OBTAINED BY USE OF
    COLORED PLASTIC MATERIAL RATHER THAN PAINTING.

3.  PIPE, SPACERS AND FITTINGS CONSTRUCTED OF
    POLYCARBONATE PLASTIC MAY BE USED IN LIEU OF
    GALVANIZED STEEL OR ALUMINUM.

4.  THE PEDESTRIAN SIGNAL HEAD SHALL BE OF THE LED
    COUNTDOWN TYPE.

5.  NEW ATTACHMENT HARDWARE AND FITTINGS SHALL BE USED.

6.  THE LIGHT EMITTING DIODE (LED) MODULES SHALL MEET THE
    REQUIREMENTS OF C&MS 732.04. THE CONTRACTOR SHALL
    PROVIDE ODOT, IN WRITING, WITH THE LED MANUFACTURER
    NAME, SERIAL NUMBER, PART NUMBER, DESCRIPTION OF LAMP,
    AND DATE OF MANUFACTURE FOR ALL LED UNITS THAT ARE TO
    BE USED IN THE SIGNAL HEAD PRIOR TO INSTALLATION, FOR
    ACCEPTANCE AND WARRANTY PURPOSES.

PAYMENT FOR ITEM 632 PEDESTRIAN SIGNAL HEAD (LED),
(COUNTDOWN), TYPE D2, AS PER PLAN SHALL BE MADE FOR
THE NUMBER OF COMPLETE SIGNAL HEAD FURNISHED AND
INSTALLED, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS
AND NEW ATTACHMENT HARDWARE.~~

Designer Note:
~~


442-19
632 RELAMP EXISTING SIGNAL SECTION WITH LED MODULE,
BY LENS TYPE, AS PER PLAN^^

THIS ITEM OF WORK SHALL CONSIST OF REPLACING THE 12-INCH
LENS AND INCANDESCENT LAMP IN AN EXISTING SIGNAL HEAD
SECTION WITH A 12-INCH LED MODULE.

THE LIGHT EMITTING DIODE (LED) MODULES SHALL MEET THE
REQUIREMENTS OF C&MS 732.04. AN LED MODULE SHALL BE
FURNISHED AND INSTALLED FOR THE TYPE OF SIGNAL LENS
SPECIFIED IN THE BID ITEM DESCRIPTION. [THE EXISTING
REFLECTOR UNIT AND LENS SHALL BE REMOVED AND RETURNED
TO THE MAINTAINING AGENCY. THE EXISTING INCANDESCENT
LAMP SHALL BE DISPOSED OF BY THE CONTRACTOR.]

THE DEPARTMENT WILL MEASURE "RELAMP EXISTING SIGNAL
HEAD WITH LED MODULES, BY LENS TYPE, AS PER PLAN" BY THE
NUMBER OF COMPLETE UNITS FURNISHED AND INSTALLED, AND
WILL INCLUDE ALL HARDWARE AND LAMPS AS SPECIFIED.~~

Designer Note:
Since maintaining agencies will use different combinations of LED/incandescent lamp
and aluminum/polycarbonate signal sections, this note will allow the designer to
choose the various options that will provide the maintaining agency with features
that they prefer. Items that are enclosed in brackets [ ] should be carefully
considered and retained or deleted based on maintaining agency preferences. Care
should be taken not to include duplicate requirements for the same item.~~


442-20
809 ATC CONTROLLER, AS PER PLAN^^

THE CONTROLLER UNIT SHALL BE FURNISHED AND INSTALLED
PER SS 809 AND BE LISTED ON THE TRAFFIC AUTHORIZED
PRODUCTS (TAP) LIST.

THE CONTROLLER SHALL BE AN ECONOLITE COBALT AND
COMPATIBLE WITH THE CABINET TYPE BEING INSTALLED.~~

Designer Note:
This note shall be used at all locations to be owned and maintained by ODOT. ODOT
has Statewide Proprietary approval for Econolite controllers.~~


442-21
633 CABINET, TYPE 33X, AS PER PLAN^^

THE CABINET SHALL BE FURNISHED AND INSTALLED ACCORDING
TO CMS 633 AND 733, AND BE LISTED ON THE TRAFFIC
AUTHORIZED PRODUCTS LIST (TAP).

THE CABINET SHALL BE FURNISHED WITH AN EDI MONITOR AS
ALLOWED ON THE TAP/APPROVED PRODUCTS LIST.

THE CONTRACTOR SHALL NOT REASSIGN THE CABINET
DETECTOR INPUTS IN ORDER TO REDUCE THE NUMBER OF
2-CHANNEL DETECTOR UNITS SUPPLIED AND SHALL USE THE
STANDARD CALTRANS INPUT FILE DESIGNATIONS FOLLOWING
PLAN INSERT SHEET 203324.

PAYMENT FOR ITEM 633 CABINET, TYPE 33X, AS PER PLAN WILL
BE AT THE CONTRACT BID PRICE PER EACH COMPLETE AND IN
PLACE INCLUDING ALL CONNECTIONS TESTED AND ACCEPTED.~~

Designer Note:
This note shall be used at ODOT maintained intersections in Caltrans Districts.
Designate in the Note and Item which cabinet Type: 332 or 336. ODOT has Statewide
Proprietary Approval for EDI Monitors.~~


442-22
633 CABINET, TYPE TS-2, AS PER PLAN^^

THE CABINET SHALL BE FURNISHED AND INSTALLED ACCORDING
TO CMS 633 AND 733 AND BE LISTED ON THE TRAFFIC
AUTHORIZED PRODUCTS LIST (TAP).

THE GROUND-MOUNTED CABINET SHALL BE A NEMA TS-2, TYPE 1,
CABINET SIZE 7 WITH 16 LOAD SWITCH BAYS, LED UNDER-SHELF
LIGHTING, POWER HARNESSES FOR BOTH TS2 TYPE 1 AND TYPE 2
CONTROLLERS AND SHALL HAVE A MINIMUM OF THREE SHELVES.

EACH CABINET SHALL COME EQUIPPED WITH TWO 16-CHANNEL
CABINET DETECTOR RACKS (CDR) INCLUDING BUS INTERFACE
UNITS (BIU). THE LOOP DETECTOR TERMINATION PANEL FOR THE
SECOND DETECTOR RACK SHALL BE OMITTED.

THE CABINET SHALL BE FURNISHED WITH AN EDI MMU AS
ALLOWED ON THE TAP/APPROVED PRODUCTS LIST.

PAYMENT FOR ITEM 633 CABINET, TYPE TS-2, AS PER PLAN WILL
BE AT THE CONTRACT BID PRICE PER EACH COMPLETE AND IN
PLACE INCLUDING ALL CONNECTIONS TESTED AND ACCEPTED.~~

Designer Note:
This note shall be used at ODOT maintained intersections in NEMA Districts. ODOT
has Statewide Proprietary Approval for EDI MMUs. If a different size cabinet is
desired, change the Plan Note to reflect it, including 12 load switch bays for
pole mounted cabinets.Optional: Provide a Hand/On/Auto switch within signal 
controller cabinet and dedicated circuit breaker for highway lighting.
Dedicate one leg of the 120 V power service to the traffic signal and one 
leg to the highway lighting. Do not power lights through the UPS.  ~~


442-25
809 PREEMPTION^^

THIS ITEM OF WORK SHALL CONSIST OF FURNISHING AND
INSTALLING PREEMPTION EQUIPMENT IN THE LOCATIONS
AND LOCAL CONTROLLERS AS SHOWN IN THE PLANS. THE
PREEMPTION SHALL CONFORM TO ODOT SUPPLEMENTAL 
SPECIFICATION 809 AND SHALL UTILIZE COMMUNICATIONS TO
IDENTIFY THE PRESENCE OF AN EMERGENCY PRIORITY VEHICLE.
IT SHALL CAUSE THE TRAFFIC SIGNAL CONTROLLER TO SELECT
A PRE-PROGRAMMED PREEMPTION PLAN THAT WILL DISPLAY AND
HOLD THE DESIRED SIGNAL PHASE FOR THE DIRECTION OF THE
EMERGENCY VEHICLE.

THE COMMUNICATIONS MEDIUM SHALL EMPLOY EITHER SOUND,
LIGHT OR RADIO DETECTION TECHNIQUES TO DETERMINE AND
LOG THE PRESENCE OF THE EMERGENCY VEHICLE. THE SYSTEM
SHALL DETECT THE PRESENCE OF THE VEHICLE THROUGH AN
EMITTING DEVICE LOCATED ON THE EMERGENCY VEHICLE. THE
SYSTEM SHALL ACTIVATE THE PREEMPTION SEQUENCE BY
APPLYING A SIGNAL TO ONE OF THE CONTROLLER'S PREEMPT
DISCRETE INPUTS. THE SYSTEM SHALL BE COMPLETELY
COMPATIBLE WITH THE CONTROLLER.

THE EQUIPMENT SHALL BE SHELF OR RACK MOUNTED AND
EASILY REMOVABLE AND REPLACEABLE WITHIN THE CABINET.
SUPPLY EQUIPMENT COMPLETELY WIRED IN THE CONTROLLER
CABINET AND TESTED. THE SYSTEM SHALL BE CAPABLE OF
PREEMPTING AND RECEIVING PRIORITY FOR EACH APPROACH
TO THE INTERSECTION. IT SHALL BE POSSIBLE TO DETECT
THE EMERGENCY VEHICLE AT LEAST 2000 FEET FROM THE
INTERSECTION IN AN 80dB-A NOISE ENVIRONMENT.

ALL PREEMPTION PLANS SHOULD BE PROGRAMMED TO
PREVENT THE YELLOW TRAP, UNLESS AS DIRECTED BY THE
DISTRICT TRAFFIC ENGINEER. YELLOW TRAP PREVENT WILL
FORCE THE TRANSITION THROUGH YELLOW CHANGE AND RED
CLEARANCE FOR RESOLUTION OF YELLOW TRAP IF ANY PHASE
OPPOSING THE PREEMPTION CLEARANCE PHASE(S) IS ACTIVE
AND DISPLAYING A GREEN OR FLASHING YELLOW ARROW
INDICATION WHEN THE PREEMPTION PLAN IS ACTIVATED AND
THE PREEMPTION CLEARANCE PHASE(S) ARE GREEN.

SUPPLY EACH INTERSECTION SHOWN IN THE PLANS WITH THE
FOLLOWING COMPONENTS, EACH BID SEPARATELY:

1.  PREEMPT RECEIVING UNIT.

2.  PREEMPT DETECTOR CABLE.

3.  PREEMPT PHASE SELECTOR ASSEMBLY AND INTERFACE
    WIRING PANEL.

4.  CONFIRMATION LIGHT.

IF A LIGHT-ACTIVATED SYSTEM IS SPECIFIED, THE CONTRACTOR
SHALL INVENTORY THE CITY'S EXISTING EMITTERS TO DETER-
MINE COMPATIBILITY WITH THE PROPOSED SYSTEM. IF EXISTING
EMITTERS ARE FOUND TO BE NOT COMPATIBLE, THEN THE CITY
SHALL BE SUPPLIED (AT COSTS INCIDENTAL TO THE SYSTEM)
WITH THE EMITTERS, TRANSMITTERS, SWITCHES, WIRING AND
ALL REQUIRED VEHICLE EQUIPMENT FOR THE FOLLOWING
EMERGENCY VEHICLES. THE CITY SHALL BE RESPONSIBLE FOR
INSTALLING VEHICLE EQUIPMENT.

IF A RADIO-ACTIVATED SYSTEM IS SPECIFIED, THE CONTRACTOR
SHALL SUPPLY THE ABOVE EMERGENCY VEHICLES WITH
EMITTERS AT COST INCIDENTAL TO THE SYSTEM.

IF A SOUND-ACTIVATED SYSTEM IS SPECIFIED, THE CONTRACTOR
SHALL INVENTORY THE ABOVE EMERGENCY VEHICLES TO DETER-
MINE COMPATIBILITY OF THE SIRENS WITH THE SYSTEM. EACH
VEHICLE THAT IS DETERMINED TO BE NOT COMPATIBLE SHALL
BE SUPPLIED WITH NEW SIRENS AT COST INCIDENTAL TO THE
SYSTEM.

IF A LIGHT, RADIO, OR SOUND ACTIVATED SYSTEM IS NOT
SPECIFIED, THEN THE CONTRACTOR SHALL SUPPLY A RADIO
ACTIVATED SYSTEM.

THE CITY SHALL BE SUPPLIED WITH SOFTWARE REQUIRED TO
CALIBRATE, LOG, AND OPERATE THE SYSTEM. TWO (2) OPERATING
AND INSTRUCTION MANUALS SHALL BE SUPPLIED WITH THE
SOFTWARE.

THE CONTRACTOR SHALL THOROUGHLY TEST THE INSTALLED
SYSTEM. AS A MINIMUM, THE CONTRACTOR SHALL VERIFY
THAT ALL CONNECTIONS ARE PROPERLY MADE TO THE CON-
TROLLER CABINETS. THE CONTRACTOR SHALL CHECK THAT THE
RANGE SETTING IS PROPER FOR EACH INTERSECTION. THE
CONTRACTOR SHALL DETERMINE THAT ALL PHASE SELECTORS
ARE SELECTING THE PROPER PHASE AND TIMING ACCURATELY.
THE CONTRACTOR SHALL VERIFY THAT ALL VEHICLE EMITTERS
ARE BEING PROPERLY DETECTED.

IF THE PROPOSED PREEMPT SYSTEM IS NOT COMPATIBLE WITH
THE EXISTING SYSTEM, THE CONTRACTOR SHALL PROVIDE
TRAINING FOR UP TO FIFTEEN (15) PERSONS IN THE OPERATION
OF THE SYSTEM. IT SHALL BE PROVIDED WITHIN 48 HOURS OF
THE INSTALLATION OF THE SYSTEM. IT SHALL CONSIST OF HANDS-
ON INSTRUCTION FOR A MINIMUM OF SIXTEEN (16) HOURS. THE
CONTRACTOR SHALL PROVIDE TRAINING FOR UP TO FOUR (4)
PERSONS IN THE INSTALLATION AND MAINTENANCE OF THE
SYSTEM. IT SHALL CONSIST OF A MINIMUM OF EIGHT (8) HOURS
OF INSTRUCTION. TRAINING SHALL BE SUPPLIED WITHIN SEVEN
(7) DAYS OF THE INSTALLATION OF THE SYSTEM. ALL TRAINING
SHALL BE HELD IN A CITY SUPPLIED LOCATION. TRAINING SHALL
BE CONDUCTED BY SOMEONE WHO HAS PERFORMED THIS
WITHIN THE LAST YEAR AND DOES IT ON A REGULAR BASIS. THE
COST OF TRAINING, INCLUDING COURSE MATERIAL, TRAVEL
SUBSISTENCE AND RELATED COSTS, SHALL BE ENTIRELY BORNE
BY THE CONTRACTOR AND SHALL BE INCIDENTAL TO THE
PREEMPTION EQUIPMENT.

	EMERGENCY VEHICLE PREEMPTION AGENCY INFO

EMERGENCY AGENCY CONTACT INFO 
(TYP. FIRE DEPT.
	                                   
					   EXISTING   PROPOSED
PREEMPTION TYPE (RADIO, LIGHT, OR SOUND)
	 	 
PREEMPTION MODEL/MAKE
	 	 
NUMBER OF INTERSECTIONS WITH EVPE
	 	 
NUMBER OF VEHICLE EMITTERS
	 	 
      REFER TO TEM 403-6 FOR ALL EVPE REQUIREMENTS, 
      WHICH INCLUDES SYSTEM AND QUANTITY LIMITS

PAYMENT FOR ITEM 809 PREEMPTION SHALL BE MADE AT THE
CONTRACT UNIT PRICE FOR EACH PREEMPTION IN PLACE AND
FULLY OPERATIONAL AS SHOWN IN THE PLANS, EXCEPT FOR
THOSE ITEMS BID SEPARATELY.~~

Designer Note:
This note describes a generic bid item for preempt systems. The quantity in the
plans should be one each for the system; not the number of intersections. See
Part 403-6 for more designer guidance. See Part 120-4 for more information on
proprietary bid items by EVPE. The Designer shall coordinate with the Emergency 
Agency and fill-in applicable information in the "Emergency Vehicle Preemption 
Agency Info" table above. ~~


442-26
809 PREEMPTION RECEIVING UNIT^^

RECEIVING UNITS SHALL CONSIST OF A LIGHTWEIGHT, WEATHER-
PROOF AND DIRECTIONAL ASSEMBLY. EACH RECEIVING UNIT
SHALL BE 360 DEGREE ADJUSTABLE. THE RECEIVING UNIT SHALL
BE CAPABLE OF SENDING THE PROPER ELECTRICAL SIGNAL TO
THE TRAFFIC SIGNAL CONTROLLER VIA THE PREEMPTION
DETECTOR CABLE. RECEIVING UNITS SHALL BE SUPPLIED WITH
MAST ARM MOUNTING HARDWARE AS SHOWN IN THE PLANS.

FURNISH PREEMPTION RECEIVING UNITS WITH 60-MONTH
WARRANTIES OR FOR THE MANUFACTURER'S STANDARD
WARRANTY WHICHEVER IS GREATER. ENSURE THAT THE
WARRANTY PERIOD BEGINS ON THE DATE OF SHIPMENT TO THE
PROJECT. ENSURE THAT EACH UNIT HAS A PERMANENT LABEL
OR STAMP INDICATING THE DATE OF SHIPMENT.

PAYMENT FOR ITEM 809 PREEMPTION RECEIVING UNIT SHALL BE
AT THE CONTRACT UNIT FOR EACH RECEIVING UNIT IN PLACE,
COMPLETELY INSTALLED AT THE LOCATION SHOWN IN THE PLANS,
WIRED, TESTED AND ACCEPTED.~~

Designer Note:
The note may be used when preemption is included for in the plans.~~


442-27
809 PREEMPTION DETECTOR CABLE^^

THIS ITEM SHALL CONSIST OF FURNISHING AND INSTALLING
PREEMPTION DETECTOR HOME RUN CABLE IN THE LOCATIONS
SHOWN IN THE PLANS. IT SHALL CONNECT THE PREEMPT
RECEIVING UNITS TO THE PHASE SELECTORS IN THE LOCAL
CONTROLLER CABINET.

PREEMPTION DETECTOR CABLE SHALL CONFORM TO ODOT
SPECIFICATION 632. ONLY ONE EXTERNAL SPLICE SHALL BE
PERMITTED BETWEEN PREEMPTION RECEIVER UNIT AND
CONTROLLER CABINET. THIS SPLICE SHALL MEET THE
REQUIREMENTS OF C&MS 632.23 USING A WATERPROOF EPOXY
SPLICE KIT. THE CABLE SHALL BE APPROVED FOR BOTH
OVERHEAD AND UNDERGROUND USE. THE JACKET SHALL
WITHSTAND EXPOSURE TO SUNLIGHT AND ATMOSPHERIC
TEMPERATURES AND STRESSES REASONABLY EXPECTED IN
NORMAL INSTALLATIONS.

PAYMENT FOR ITEM 809 PREEMPTION DETECTOR CABLE SHALL
BE MADE AT THE CONTRACT UNIT PRICE PER FOOT FOR THE
CABLE FURNISHED, IN PLACE, ALL CONNECTIONS MADE AND
WIRING COMPLETED, TESTED AND ACCEPTED.~~

Designer Note:
This note may be used when preemption is included for in the plans.~~


442-28
809 PREEMPT PHASE SELECTOR^^

THIS ITEM SHALL CONSIST OF FURNISHING AND INSTALLING
PREEMPT PHASE SELECTORS INCLUDING WIRING INTERFACE
PANELS IN THE LOCAL CONTROLLER CABINET AND ALL OTHER
ACCESSORIES THAT ARE NECESSARY TO MAKE THE PREEMPT
PHASE SELECTORS COMPLETELY FUNCTIONAL AND OPERATIONAL
AS SHOWN IN THE PLANS. THIS ITEM SHALL INCLUDE THE EXTRA
CABINET SPACE NECESSARY TO BE LOCATED IN THE LOCAL
CONTROLLER CABINETS WHERE INDICATED IN THE PLANS.

THE PHASE SELECTORS SHALL CONSIST OF A MODULE OR
MODULES THAT WILL PROVIDE THE NECESSARY INPUTS TO THE
CONTROLLER. PHASE SELECTORS SHALL BE SUPPLIED WITH
SUFFICIENT QUANTITIES OF CHANNELS TO PROVIDE PREEMPTION
FOR ALL APPROACHES TO THE INTERSECTION SEPARATELY.
POWER SHALL BE OBTAINED FROM THE PHASE SELECTOR OR
PHASE SELECTOR POWER SUPPLY AND NOT FROM THE LOCAL
CONTROLLER TIMER.

THE PHASE SELECTORS SHALL HAVE FRONT PANEL INDICATORS
FOR ACTIVE PREEMPT CHANNEL STATUS. IT SHALL HAVE TEST
SWITCHES TO ACTIVATE ALL PREEMPT CHANNELS.

FURNISH PREEMPT PHASE SELECTORS WITH 60-MONTH
WARRANTIES OR FOR THE MANUFACTURER'S STANDARD
WARRANTY WHICHEVER IS GREATER. ENSURE THAT THE
WARRANTY PERIOD BEGINS ON THE DATE OF SHIPMENT TO THE
PROJECT. ENSURE THAT EACH UNIT HAS A PERMANENT LABEL
OR STAMP INDICATING THE DATE OF SHIPMENT.

PAYMENT FOR ITEM 809 PREEMPT PHASE SELECTOR SHALL
BE MADE AT THE CONTRACT UNIT PRICE FOR EACH PHASE
SELECTOR IN PLACE, COMPLETELY INSTALLED IN THE LOCAL
CONTROLLER SHOWN IN THE PLANS, WIRED, TESTED AND
ACCEPTED.~~

Designer Note:
This note may be used when preemption is included for in the plans.~~


442-29
809 PREEMPT CONFIRMATION LIGHT, LED^^

THIS ITEM SHALL CONSIST OF FURNISHING AND INSTALLING
PREEMPT CONFIRMATION LIGHTS INCLUDING HARDWARE AND
ALL OTHER ACCESSORIES THAT ARE NECESSARY TO MAKE THE
PREEMPT CONFIRMATION LIGHT COMPLETELY FUNCTIONAL AND
OPERATIONAL AS SHOWN IN THE PLANS.

A CONFIRMATION LIGHT SHALL BE SUPPLIED FOR EACH INTER-
SECTION TO INDICATE THAT THE EMERGENCY VEHICLE HAS
ACHIEVED CONTROL OF THE TRAFFIC SIGNAL.

THE CONFIRMATION LIGHT SHALL BE A WEATHER TIGHT LIGHTING
FIXTURE. IT SHALL BE SUPPLIED WITH A GLOBE, LED LAMP
AND MOUNTING HARDWARE TO ATTACH TO THE TRAFFIC SIGNAL
MAST ARM. THE CONFIRMATION LIGHT SHALL BE POWERED BY A
LOAD SWITCH IN THE TRAFFIC SIGNAL CONTROLLER. SIGNAL
CABLE CONFORMING TO 732.19 SHALL BE USED FOR CONFIR-
MATION LIGHTS. A MINIMUM OF 4-CONDUCTOR CABLE SHALL BE
USED WITH THE GREEN WIRE SERVING AS THE SAFETY GROUND
CONDUCTOR. PAYMENT FOR ITEM 809 PREEMPT CONFIRMATION
LIGHT, LED SHALL BE MADE AT THE CONTRACT UNIT PRICE FOR
EACH LIGHT IN PLACE, COMPLETELY INSTALLED IN THE LOCATION
SHOWN IN THE PLANS, WIRED, TESTED AND ACCEPTED.~~

Designer Note:
This note may be used when requested by the maintaining agency. 
The globe may be clear or the Local Agency's choice of color. 
The signal cable is a separate pay item.~~


442-30
PULL BOX, 24" X 35" X 26"^^

PULL BOXES SHALL HAVE NOMINAL OPENING DIMENSIONS OF
24 INCHES BY 35 INCHES. MATERIALS SHALL CONFORM TO 725.06,
725.07 OR 725.08. THE WORD "TRAFFIC" SHALL BE INTEGRALLY
CAST AS PART OF THE COVER OR SECURELY FASTENED WITH
CORROSION RESISTANT HARDWARE. THE SUPPLIED PULL BOXES
SHALL SUPPORT A 20,000-POUND MINIMUM VERTICAL LOADING
WITHOUT PERMANENT DAMAGE OR DEFLECTION TO THE UNIT.
DISPOSE OF SURPLUS MATERIAL AND RESTORE DISTURBED
FACILITIES AND SURFACES.

THE LARGEST BEND RADIUS POSSIBLE SHALL BE MAINTAINED
FOR THE FIBER OPTIC CABLE.

ALL COSTS RESULTING FROM THE ABOVE REQUIREMENTS SHALL
BE INCLUDED IN THE UNIT PRICE BID PER EACH FOR ITEM 625
"PULL BOX, 24" X 35" X 26".~~

Designer Note:
The pull box cited in this note is bell shaped at the
bottom to help maintain fiber optic cable minimum bend
radii. Any pull box where a splice is required or a
change in cable direction is made should use this larger
pull box.~~


442-31
632 POLE ENTRANCE FITTING^^

A POLE ENTRANCE FITTING SHALL BE PROVIDED IN ACCORD-
ANCE WITH THE PLAN DETAILS TO ALLOW FIBER OPTIC CABLE
ENTRANCE INTO BOTH EXISTING AND PROPOSED STEEL POLES.
IN PROPOSED POLES THE CONTRACTOR SHALL HAVE THE 2-INCH
ENTRANCE HOLES SHOWN IN THE DETAILS PRE-MANUFACTURED.
BLIND HALF COUPLINGS SHALL BE WELDED INTO ANY NEW
STRAIN POLES SUPPLIED AS PART OF THE PROJECT.

EXISTING STRAIN POLES SHALL REQUIRE THE CONTRACTOR
TO FIELD LOCATE THE POLE ENTRANCE HOLE AND DRILL TWO
PILOT HOLES AND USE A HOLE SAW TO CUT THE 2-INCH HOLE.
ALL NON-GALVANIZED POLE SURFACES EXPOSED AFTER CUTTING
THE HOLE SHALL HAVE THREE COATS OF ZINC ENRICHED PAINT
APPLIED.

NO POLE ENTRANCE FITTING HOLES SHALL BE LOCATED
VERTICALLY WITHIN 24 INCHES OF ANY OTHER HOLES OR BLIND
HALF COUPLINGS.

ALL COSTS TO PROVIDE A POLE ENTRANCE INCLUDING MATERIAL,
EQUIPMENT AND LABOR SHALL BE INCLUDED IN THE BID ITEM
PRICE FOR EACH ITEM 632 "POLE ENTRANCE FITTING".~~

Designer Note:
The maintaining agency may opt to have the Contractor
route drop cables down the outside of strain poles.~~


442-32
GROUNDING AND BONDING^^

THE REQUIREMENTS OF THE CONSTRUCTION AND MATERIAL
SPECIFICATIONS (C&MS) AND THE TC SERIES OF STANDARD
CONSTRUCTION DRAWINGS ARE MODIFIED AS FOLLOWS:

1.  ALL METALLIC PARTS CONTAINING ELECTRICAL CONDUCTORS
    SHALL BE PERMANENTLY JOINED TO FORM AN EFFECTIVE
    GROUND FAULT CURRENT PATH BACK TO THE GROUNDED
    CONDUCTOR IN THE POWER SERVICE DISCONNECT SWITCH.

    A.   PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN
         METALLIC CONDUITS (725.04) IN ADDITION TO THE
         CONDUCTORS SPECIFIED AND BOND THE CONDUIT TO
         THIS GROUNDING CONDUCTOR.

    B.   WHEN AN EQUIPMENT GROUNDING CONDUCTOR IS
         REQUIRED IN PLASTIC CONDUIT (725.05), THE
         INSTALLATION SHALL INCLUDE A SEPARATE EQUIPMENT
         GROUNDING CONDUCTOR IN ADDITION TO THE
         CONDUCTORS SPECIFIED.

    C.   METALLIC CONDUIT CARRYING THE LOOP WIRES FROM
         IN THE PAVEMENT TO THE PULL BOX SPLICE LOCATION
         WILL ONLY BE BONDED AT THE PULL BOX END, AND WILL
         NOT CONTAIN AN EQUIPMENT GROUNDING CONDUCTOR.

    D.   IF MULTIPLE CONDUIT RUNS BEGIN AND END AT THE
         SAME POINTS, ONLY ONE EQUIPMENT GROUNDING
         CONDUCTOR IS REQUIRED.

    E.   IF AN EQUIPMENT GROUNDING CONDUCTOR IS NEEDED
         IN CONDUIT BETWEEN SIGNALIZED INTERSECTIONS FOR
         UNDERGROUND INTERCONNECT CABLE, THE GROUNDING
         SYSTEM FOR EACH SIGNALIZED INTERSECTION WILL BE
         SEPARATED ABOUT MIDWAY BETWEEN THE INTERSECTIONS.

    F.   THE MESSENGER WIRE AT SIGNALIZED INTERSECTIONS
         WILL BE USED AS THE CONDUCTIVE PATH FROM CORNER
         TO CORNER IF CONDUIT IS NOT PROVIDED UNDER THE
         ROADWAY. WHEN CONDUIT CONNECTS THE CORNERS OF
         AN INTERSECTION, AN EQUIPMENT GROUNDING
         CONDUCTOR SHALL BE USED IN THE CONDUIT.

2.  CONDUITS.

    A.   THE 725.04 CONDUIT SHALL HAVE GROUNDING BUSHINGS
         INSTALLED AT ALL TERMINATION POINTS. THE BUSHING
         MATERIAL SHALL BE COMPATIBLE WITH GALVANIZED STEEL
         CONDUIT AND THE GROUNDING LUG MATERIAL SHALL BE
         COMPATIBLE FOR USE WITH COPPER WIRE. THREADED OR
         COMPRESSION TYPE BUSHINGS MAY BE USED.

    B.   THE 725.05 CONDUIT SHALL HAVE THE INSIDE AND
         OUTSIDE DIAMETERS OF THE CONDUIT DEBURRED AT ALL
         TERMINATION POINTS.

    C.   BOTH ENDS OF METALLIC CONDUIT SHALL BE BONDED TO
         THE EQUIPMENT GROUNDING CONDUCTOR.

    D.   METALLIC CONDUIT MAY BE BONDED TO METALLIC BOXES
         THROUGH THE USE OF CONDUIT FITTINGS UL APPROVED
         FOR THIS TYPE OF CONNECTION, WITH THE BOX BONDED
         TO THE EQUIPMENT GROUNDING CONDUCTOR.

3.  WIRE FOR GROUNDING AND BONDING.

    A.   USE INSULATED, COPPER WIRE FOR THE EQUIPMENT
         GROUNDING CONDUCTOR. BONDING JUMPERS IN BOXES
         AND ENCLOSURES MAY BE BARE OR INSULATED COPPER
         WIRE. WIRE SIZE SHALL BE AS FOLLOWS:

         I.   USE 4 AWG BETWEEN THE POWER SERVICE AND
              SUPPORTS, POLES, PEDESTALS, CONTROLLER OR
              FLASHER CABINETS.

         II.  USE A MINIMUM 8 AWG BETWEEN LOOP DETECTOR PULL
              BOXES AND THE FIRST CONDUIT THAT REQUIRES A
              LARGER SIZE AS SPECIFIED IN 3.A.I ABOVE.

         III. USE A MINIMUM 8 AWG BETWEEN THE "PREPARE TO
              STOP WHEN FLASHING" INSTALLATION (INCLUDING
              SUPPORT) AND THE FIRST CONDUIT THAT REQUIRES A
              LARGER SIZE AS SPECIFIED IN 3.A.I ABOVE.

         IV.  THE INSULATION SHALL BE GREEN OR GREEN WITH
              YELLOW STRIPE(S). FOR 4 AWG OR LARGER, INSULATION
              MAY ALSO BE BLACK WITH GREEN TAPE/LABELS
              INSTALLED AT ALL ACCESS POINTS.

    B.   IN A HIGHWAY LIGHTING SYSTEM, THE EQUIPMENT
         GROUNDING CONDUCTOR SHALL BE THE SAME WIRE SIZE
         AS THE DUCT CABLE OR DISTRIBUTION CABLE CIRCUIT
         CONDUCTORS, WITH THE MINIMUM CONDUCTOR SIZE OF
         4 AWG. BONDING JUMPERS WILL BE MINIMUM SIZE 4 AWG.

4.  GROUND ROD.

    A.   A 3/4-INCH SCHEDULE 40 PVC CONDUIT WILL BE USED IN
         FOUNDATIONS AND CONCRETE WALLS FOR THE GROUNDING
         CONDUCTOR (GROUND WIRE) RACEWAY TO THE GROUND
         ROD. SHOULD METALLIC CONDUIT BE USED, BOTH ENDS OF
         THE CONDUIT SHALL BE BONDED TO THE GROUNDING
         CONDUCTOR.

    B.   THE TYPICAL GROUNDING CONDUCTOR (GROUND WIRE)
         SHALL BE 4 AWG INSULATED, COPPER.

5.  THE GREEN CONDUCTOR IN SIGNAL CABLES (CONDUCTOR #4)
    SHALL NOT BE USED TO SUPPLY POWER TO A SIGNAL
    INDICATION. IT WILL BE CONNECTED TO THE SIGNAL BODY AS
    AN EQUIPMENT GROUND IN ALUMINUM HEADS AND IT WILL BE
    UNUSED IN PLASTIC HEADS. UNUSED CONDUCTORS SHALL BE
    GROUNDED IN THE CABINET. TYPICAL USE OF CONDUCTORS
    IS AS FOLLOWS:

COND. NO.    COLOR        VEHICLE SIGNAL       PEDESTRIAN SIGNAL
   1         BLACK        GREEN BALL           #1 WALK
   2         WHITE        AC NEUTRAL           AC NEUTRAL
   3         RED          RED BALL             #1 DW/FDW
   4         GREEN        EQUIPMENT GROUND     EQUIPMENT GROUND
   5         ORANGE       YELLOW BALL          #2 DW/FDW
   6         BLUE         GREEN ARROW          #2 WALK
   7         WHITE/BLACK  STRIPE YELLOW ARROW  NOT USED

6.  POWER SERVICE AND DISCONNECT SWITCH.

    A.   AT THE POWER SERVICE LOCATION, THE GROUNDING
         CONDUCTOR (GROUND WIRE) FROM THE DISCONNECT
         SWITCH NEUTRAL (AC-) BAR TO THE GROUND ROD SHALL
         BE A CONTINUOUS, UNSPLICED CONDUCTOR. IF SPLICED,
         IT SHALL BE AN EXOTHERMIC WELD BUTT SPLICE.

    B.   THE SERVICE NEUTRAL (AC-) SHALL ONLY BE CONNECTED
         TO GROUND AT THE PRIMARY POWER SERVICE DISCONNECT
         SWITCH.

         I.   NEMA CONTROLLER CABINETS: IF A POWER SERVICE
              DISCONNECT SWITCH IS LOCATED BEFORE THE
              CONTROLLER CABINET, THE NEUTRAL (AC-) AND THE
              GROUNDING BARS IN THE CONTROLLER CABINET SHALL
              NOT BE CONNECTED TOGETHER AS SHOWN IN NEMA
              TS-2, FIGURE 5-4.

         II.  IF SECONDARY DISCONNECT SWITCHES ARE CONNECTED
              AFTER THE PRIMARY DISCONNECT SWITCH, THE NEUTRAL
              (AC-) SHALL ONLY BE GROUNDED AT THE PRIMARY
              SWITCH. EQUIPMENT GROUNDING CONDUCTORS SHALL
              BE BROUGHT TO THE PRIMARY SWITCH, BUT SHALL BE
              GROUNDED AT BOTH SECONDARY AND PRIMARY
              SWITCHES.

7.  PAYMENT - ALL MATERIALS AND WORK REQUIRED TO
    COMPLETE THE EFFECTIVE GROUND FAULT CURRENT PATH
    SYSTEM ARE INCIDENTAL TO THE CONDUCTORS INSTALLED BY
    CONTRACT.~~

Designer Note:
This note shall be used on all projects with electrical
items (631, 632, 633). Figures 498-39 through 498-42 provide
examples of wire sizes for equipment grounding conductor.~~


442-33
UNDERDRAINS FOR PULL BOXES^^

REFERENCE TRAFFIC SCD HL-30.11 FOR DETAILS ABOUT DRAINING
PULL BOXES. UNDERDRAINS FOR PULL BOXES SHALL BE USED AS
DIRECTED BY THE ENGINEER AND SHALL BE PROVIDED WHERE
THE LENGTH REQUIRED FOR A SATISFACTORY OUTLET DOES NOT
EXCEED 20 FEET. THE FOLLOWING ESTIMATED QUANTITY IS
CARRIED TO THE GENERAL SUMMARY FOR THIS PURPOSE:

ITEM 611 4" CONDUIT, TYPE E     _____ FT.~~

Designer Note:
This note should be used in areas that are prone to high water
tables or as specified and required by District staff.~~


442-40
633 UNINTERRUPTIBLE POWER SUPPLY (UPS), BATTERY
REPLACEMENT^^

IN ADDITION TO THE REQUIREMENTS OF 733.09, PROVIDE FOUR
(4) BATTERIES FOR EACH EXISTING UNINTERRUPTIBLE POWER
SUPPLY (UPS) CABINET LOCATION SELECTED.

BATTERIES SHALL BE PROVIDED FROM THE DEPARTMENT'S
QUALIFIED PRODUCT LIST.

FURNISH BATTERIES CERTIFIED BY THE MANUFACTURER TO
OPERATE OVER A TEMPERATURE RANGE OF -13 DEGREES F
TO +165 DEGREES F.

PLACE ALL BATTERIES ON BATTERY HEATER MATS IN THE
ENCLOSURE.

BATTERIES SHALL BE WARRANTED FOR FULL REPLACEMENT
FOR TWO (2) YEARS FROM DATE OF PURCHASE.

THE DEPARTMENT WILL PAY FOR ITEM 633 UNINTERRUPTIBLE
POWER SUPPLY (UPS), BATTERY REPLACEMENT AT THE
CONTRACT PRICE BID FOR EACH UPS LOCATION WHERE THE
FOUR (4) EXISTING BATTERIES ARE REPLACED. PAYMENT SHALL
BE FULL COMPENSATION FOR ALL LABOR, MATERIALS, TOOLS,
EQUIPMENT, DISPOSAL AND OTHER INCIDENTALS NECESSARY
TO REPLACE THE UPS BATTERIES COMPLETE, IN PLACE, AND
ACCEPTED.~~

Designer Note:
This note is required if the maintaining agency wishes to
replace the batteries in an existing Uninterruptible Power
Supply as part of a project.~~


442-41
633 UNINTERRUPTIBLE POWER SUPPLY (UPS), 1000 WATT,
AS PER PLAN^^

IN ADDITION TO THE REQUIREMENTS OF C&MS 633 AND 733,
POLE ATTACHMENT HARDWARE WILL BE INCLUDED FOR POLE-
MOUNTED CABINETS, AND A CABINET RISER (8-INCH MINIMUM)
AND ANCHOR BOLTS WILL BE PROVIDED FOR BASE-MOUNTED
CABINETS. BEFORE PERFORMING THE WORK, THE CONTRACTOR,
THE DISTRICT TRAFFIC ENGINEER AND THE PROJECT ENGINEER
WILL PERFORM A SITE INSPECTION TO ESTABLISH THE LOCATION
OF THE UPS CABINET AND FOUNDATION.

THE UPS CABINET SHALL INCLUDE A GENERATOR POWER PANEL
WITH A HEAVY-DUTY POWER RELAY VERSUS THE LINE VOLTAGE
GENERATOR SWITCH. THE GENERATOR INLET SHALL BE A
RECESSED PANEL WITH A DOOR THAT IS FLUSH WITH THE
EXTERNAL SIDE OF THE UPS CABINET. IT SHALL INCLUDE A
RECESSED PLUG, AUTOMATIC TRANSFER SWITCH AND A DOOR
THAT SECURELY CLOSES OVER THE POWER CORD.

THE CABINET SHALL HAVE A DOOR STOP MECHANISM AND
THERMOSTATICALLY CONTROLLED FAN.

THE CABINET SHALL INCLUDE A BATTERY BALANCING DEVICE
THAT REGULATES THE BATTERIES AND OPTIMIZES
PERFORMANCE.

AFTER FOUR (4) HOURS OF BATTERY RUNTIME, THE SYSTEM
SHALL BE PROGRAMMED TO SWITCH THE INTERSECTION FROM
FULL OPERATION TO CONTROLLER AUTOMATIC FLASH
OPERATION THROUGH THE MONITOR. THE CONTROLLER SHALL
BE PROGRAMMED SO THAT FLASH OPERATION SHALL BEGIN
ONCE THE INTERSECTION RUNS MINOR STREET GREEN (TYP.
PH. 4 &8), ALL-RED CLEARANCE, AND THEN FLASH OPERATION.

THE UPS OUTPUT NOTIFICATIONS FOR ON BATTERY, BATTERY
2-HOUR TIMER, AND LOW BATTERY SHALL BE WIRED INTO THE
TRAFFIC SIGNAL CABINET BACK PANEL OR THROUGH THE
CONTROLLER WITH A C11 TO PROVIDE SPECIAL STATUS ALARMS
FOR EACH OUTPUT INTO THE SIGNAL CONTROLLER.

THIS ITEM SHALL INCLUDE A RED LED STATUS INDICATOR LAMP
TO ALLOW MAINTENANCE PERSONNEL AND LAW ENFORCEMENT
TO QUICKLY ASSESS WHETHER A TRAFFIC SIGNAL CABINET IS
BEING POWERED BY A UPS. THE LED HOUSING SHALL BE NEMA
4X, IP65 OR IP66, RATED FOR OUTDOOR USE AND BE TAMPER/
SHATTER RESISTANT. IT SHALL BE A DOMED ENCLOSURE
CONTAINING A RED LENS WITH LED THAT IS VISIBLE FROM 100
FOOT MINIMUM. THE ENCLOSURE AND LED MODULE SHOULD
BE PLACED ON THE SIDE OF THE UPS CABINET FACING TOWARDS
THE MAINLINE ROADWAY AND SEALED FROM WATER INTRUSION.
IT SHOULD BE WIRED USING MINIMUM 20GA STRANDED,
INSULATED HOOKUP WIRE TO THE STATUS RELAY OUTPUTS OF
THE UPS. THE WIRES SHALL BE TERMINATED BY LUGS AT THE
DISPLAY END AND PERMANENTLY LABELED "BACKUP POWER
STATUS DISPLAY," WITH WIRE POLARITY INDICATED. THE RED
LED SHALL ONLY ILLUMINATE TO INDICATE THE CABINET IS
OPERATING UNDER UPS BACKUP POWER (THE "BACKUP"
OPERATING CONDITION). THIS ITEM INCLUDES PROGRAMMING
THE UPS STATUS RELAY OUTPUTS TO PRODUCE THE LAMP
STATUS DISPLAYS. THESE STATUS DISPLAYS WILL BE SOLID 100%
DUTY CYCLE (NOT FLASHING) DISPLAYS. THE OPERATING
VOLTAGE OF THE LED LAMP SHALL BE 120V AC UNLESS
OTHERWISE INDICATED.~~

Designer Note:

This note contains the base template and has some District/Agency-specific
options to be determined by the owner/maintainer of the traffic signal.
ODOT has Statewide Proprietary approval for Alpha UPSs. The 5th paragraph 
can be modified accordingly for District/Agency preference.


The battery balancer is an optional item that can be removed from the spec if desired.

Additional optional items to place in the note: The enclosure shall have sliding drawers
to allow easy removal and installation of batteries and access to cable in the bottom of
the cabinet, OR a Remote Monitoring System is to be included with the installation, which
includes all equipment, setup, and testing.

This note is intended to allow maintaining agencies to include an indicator lamp for visual
confirmation of UPS status if desired. Maintaining agencies may change or omit the recommended
display, if desired, on either new or existing cabinets. The specified domed lens has better
visibility than a flat lens, but is slightly more vulnerable to vandalism. A flat indicator
lamp may be specified instead, if visibility is good and/or vandalism is a concern. If vandalism
is a specific concern, external indicator lamps should not be used. The lamp may be placed on
the cabinet roof instead of the wall, if desired. The operating voltage may be changed if required.~~


442-42
TEST HOLE PERFORMED^^

IT IS ANTICIPATED THAT THE CONTRACTOR WILL ENCOUNTER
UNDERGROUND UTILITIES WHILE EXCAVATING FOR SIGNAL
SUPPORT FOUNDATIONS OR SIMILAR FOUNDATIONS. AFTER
ACCURATELY IDENTIFYING THE PROPOSED LOCATION OF THE
FOUNDATION, AS SHOWN IN THE PLANS AND AFTER MODIFYING
THAT LOCATION, IF NECESSARY, BASED ON THE FIELD MARKING
OF UNDERGROUND UTILITY LOCATION, THE CONTRACTOR
DISCOVERS A UTILITY CONFLICT DURING THE EXCAVATION
OPERATION, THE CONTRACTOR WILL BE COMPENSATED FOR 
EACH PARTIAL FOUNDATION EXCAVATION ACCORDING TO THE
BID PRICE. 

BEFORE THE CONTRACTOR BEGINS THE EXCAVATION AT THE
MODIFIED LOCATION, THE CONTRACTOR SHALL VERIFY THAT
THERE WILL BE NO OVERHEAD UTILITY CONFLICTS RESULTING 
FROM THE NEW SIGNAL SUPPORT LOCATION. NEW SUPPORT
LOCATIONS ARE TO BE APPROVED BY THE ENGINEER. 

THE WORK WILL INCLUDE BACKFILLING, COMPACTING, AND
RESTORATION OF THE EXCAVATION TO THE SITE’S ORIGINAL
CONDITION.

EXCAVATIONS SHALL NOT BE LEFT OPEN OVERNIGHT. 

PAYMENT FOR THIS ITEM SHALL BE AT THE UNIT PRICE BID PER
EACH ITEM 632 TEST HOLE PERFORMED TO BE USED AT THE
DIRECTION OF THE ENGINEER.~~

Designer Note:
The note and contingency quantity can be included if it is anticipated that utility
conflicts may exist. 

Designers must understand that this note provides for contingency quantities during
Construction. It does not represent a Subsurface Utility Location Services (SULS) Test Hole,
which is usually performed during the Preliminary Engineering step of project Design. See
TEM Section 440.~~


442-43
632 AUGER-IN FOUNDATION, 8-INCH DIAMETER BY (DEPTH
IN FEET)^^

THIS ITEM CONSISTS OF SUPPLYING AND INSTALLING A POLE
FOUNDATION IN UNDISTURBED SOIL BY USE OF A POWER ROTARY
DRILL RIG ("KELLY DRIVE"), AT THE LOCATION SPECIFIED IN THE
PLANS. PROVIDE AN AUGER-IN FOUNDATION OF 8-INCH MINIMUM
OUTSIDE DIAMETER AND SHAFT LENGTH AS SPECIFIED IN THE
ITEM DESCRIPTION. INTEGRAL CABLEWAY CUTOUTS OF 2-INCH
BY 8-INCH (MINIMUM) SHALL BE PRESENT ON OPPOSITE SIDES OF
THE SHAFT BEGINNING AT 30-INCH DEPTH. PROVIDE A SHAFT AND
ALL HARDWARE HOT-DIP GALVANIZED FINISHED PER ASTM A153.
ASSURE THE BASE PLATE CAN ACCOMMODATE 12-3/4-INCH TO
17-INCH BOLT CIRCLES AS SHOWN ON STANDARD CONSTRUCTION
DRAWINGS HL-10.13, TC-83.20, AND TC-21.21.

INSTALL PER MANUFACTURER'S INSTRUCTIONS, WITH FREQUENT
CHECKING AND ADJUSTMENT DURING AUGURING, TO ASSURE A
PLUMB POLE INSTALLATION. AUGER IN THE FOUNDATION UNTIL
THE TOP OF THE BASE PLATE IS AT THE FINAL GRADE ELEVATION.
ALIGN THE BASE PLATE SIDE PARALLEL TO THE ROADWAY AND
ALIGN CABLEWAY CUTOUTS WITH UNDERGROUND CONDUITS
SHOWN IN THE PLANS. IF NO CONDUITS APPEAR IN THE PLANS,
THEN INSTALL THE CABLEWAY CUTOUTS PARALLEL TO THE
ROADWAY. CLEAN THE INSIDE OF THE INSTALLED FOUNDATION
OF SOIL AND DEBRIS TO THE BOTTOM OF THE CABLEWAY
CUTOUTS.

DIG CONDUIT TRENCH BY HAND USING A TRENCHING SHOVEL
WITHIN 2 FEET OF THE INSTALLED FOUNDATION. IF MACHINE-
TRENCHING IS PERFORMED WITHIN 2 FEET OF THE FOUNDATION,
RE-INSTALL THE AUGER-IN FOUNDATION A SHORT DISTANCE
AWAY, AS DIRECTED BY THE ENGINEER, OR REPLACE WITH A
CAST-IN-PLACE CONCRETE 632 PEDESTAL FOUNDATION.
FOUNDATION AND CONDUIT RELOCATION AND/OR REPLACEMENT
FOUNDATIONS NECESSITATED BY MACHINE-TRENCHING TOO
CLOSE TO THE ORIGINAL FOUNDATION ARE PERFORMED AT THE
CONTRACTOR'S EXPENSE.

PROVIDE AN AUGER-IN FOUNDATION MEETING THESE
SPECIFICATIONS AND MANUFACTURED BY AB CHANCE,
MILLERBERND, PELCO, OR AN APPROVED EQUAL.

PAYMENT FOR THIS ITEM IS FOR EACH UNIT SPECIFIED AT THE
UNIT BID PRICE, COMPLETE AND IN PLACE.~~

Designer Note:
Use this specification in place of Item 632 Pedestal Foundation only when necessary,
such as for knockdown replacement and similar situations that require a quick
installation. The concrete 632 Pedestal Foundation item is standard for new design,
but the Auger-In Foundation is suitable for maintenance installations. The minimum
specified length is five feet (60 inches) in urban areas and 6 feet (72 inches) in
rural areas. For maintenance purposes, these two sizes are generic. Generally, the
designer also specifies a breakaway Transformer Base as part of the complete assembly.
The designer shall perform basic 90mph design wind speed overturning moment calculations
for all sign, signal, or light pole assemblies mounted on auger-in bases using
the AASHTO LRFDLTS-1, with parameters per TC-81.22. Use this design overturning moment and
local soils data to determine the required foundation dimensions using the Drilled Shaft
Foundation Design Spreadsheet provided by the Office of Roadway Engineering (ORE); the
spreadsheet is available for download from the ORE website.

District approval is required before using this item in construction plans; provide
copies of the spreadsheet and soils data to the District.~~


442-44
632 SIGNAL SUPPORT FOUNDATION^^

PRIOR TO ORDERING THE SIGNAL SUPPORTS, THE CONTRACTOR
SHALL CONTACT OUPS TO HAVE ALL THE UTILITIES LOCATED IN
THE FIELD. THEN THE CONTRACTOR SHALL MEET THE PROJECT ENGINEER TO LOCATE
THE PROPOSED SUPPORT LOCATIONS TO INSURE THERE ARE NO
CONFLICTS WITH UTILITIES. IF THERE ARE ISSUES, THE PROJECT
ENGINEER SHALL PROVIDE GUIDANCE AS TO THE RELOCATION
OF THE SUPPORTS.


DUE TO THE FURTHER POSSIBILITY OF CONFLICT WITH EXISTING OR PROPOSED
UNDERGROUND OBSTRUCTIONS (INCLUDING THE POSSIBILITY OF UNRECORDED OBSTRUCTIONS) 
WHICH COULD AFFECT THE LOCATION OF THE FOUNDATION FOR THIS ITEM, AND CONSEQUENTLY, 
THE DESIGN OF THE SUPPORT AND/OR ARMS, THE CONTRACTOR SHALL NOT PLACE FINAL 
ORDERS FOR THE ITEM UNTIL THE FOUNDATIONS HAVE BEEN INSTALLED, AT FINAL GRADE, 
AND THE CONTRACTOR HAS RECEIVED, FROM ENGINEER, WRITTEN NOTICE TO PROCEED WITH 
THE ORDERS FOR THE ITEM. 

IF ANY FOUNDATION LOCATIONS MUST BE ADJUSTED, THE CONTRACTOR SHALL NOTIFY 
THE ENGINEER AND MAINTAINING AGENCY, WHO WILL DETERMINE THE REVISED LOCATION 
AND IF NEEDED, THE SUPPORT DESIGN. THE CONTRACTOR WILL NOT BE RESPONSIBLE 
FOR DETERMINING THE REVISED DESIGN. THE ENGINEER WILL INFORM THE CONTRACTOR 
OF ANY CHANGES NECESSARY AND AUTHORIZE THE CONTRACTOR TO ORDER THE SUPPORT. 

THE CONTRACTOR SHALL, WHEN DEVELOPING THE PROGRESS SCHEDULE, 
AND THOSE OF SUBCONTRACTORS, ENSURE THAT THE FOUNDATIONS 
ARE INSTALLED AT THE EARLIEST TIME AS IS FEASIBLE AND PRACTICAL, AND SHALL 
INCLUDE SUFFICIENT TIME IN THE PROGRESS SCHEDULE FOR ORDERING, MANUFACTURING, 
DELIVERY, AND INSTALLATION OF THE SUPPORT ITEMS AFTER THE FOUNDATIONS ARE IN PLACE.

NO PAYMENTS FOR DELIVERED MATERIALS FOR THE FOUNDATION OR SUPPORT ITEMS SHALL BE 
MADE UNTIL THE FOUNDATIONS ARE IN PLACE, AND IF CHANGES IN THE DESIGN OF 
THIS ITEM ARE REQUIRED, NO PAYMENT SHALL BE MADE FOR THE ITEMS MANUFACTURED 
TO THE ORIGINAL DESIGN.

PAYMENT WILL BE AT THE CONTRACT UNIT PRICE AND WILL BE
FULL COMPENSATION FOR ALL LABOR, MATERIALS, TOOLS,
EQUIPMENT AND OTHER INCIDENTALS NECESSARY FOR EACH
SUPPORT FURNISHED, IN PLACE, COMPLETE AND ACCEPTED.~~

Designer Note:
This note should be used when any new signal supports are to be installed
If note 442-42 test hole performed is used, this note may be deleted.~~


442-46
632 SIGNAL SUPPORT, (BY TYPE), AS PER PLAN^^

IN ADDITION TO PROVISIONS OF THE ODOT C&MS, FURNISH AND
INSTALL SIGNAL POLES AS SPECIFIED IN THE PLANS.

THE SIGNAL SUPPORT DESIGNER SHALL PROVIDE DRAWINGS OF
A SIGNAL SUPPORT WITH STRUCTURAL ASPECTS OF THE DESIGN
AND MATERIALS IN COMPLIANCE WITH THE AASHTO LRFDLTS-1.

SUBMIT, TO THE ENGINEER PRIOR TO INCORPORATION: TWO
COPIES OF THE SIGNAL SUPPORT DRAWINGS AND SHOP
DRAWINGS, WHICH IDENTIFY AND DESCRIBE EACH
MANUFACTURED SIGNAL SUPPORT AND SIGNAL SUPPORT ITEM
WHICH IS BEING INCORPORATED INTO THE CONSTRUCTION. THE
SIGNAL SUPPORT DRAWINGS AND SHOP DRAWINGS SHALL EACH
BE REVIEWED, SEALED, STAMPED, AND DATED BY TWO OHIO
REGISTERED PROFESSIONAL ENGINEERS.

PAYMENT FOR ITEM 632 "SIGNAL SUPPORT, (BY TYPE), AS PER
PLAN" SHALL BE MADE AT THE CONTRACT UNIT PRICE PER EACH
COMPLETE AND IN PLACE, AND SHALL INCLUDE ALL SIGNAL
SUPPORT DESIGN, LABOR, MATERIALS, AND EQUIPMENT
NECESSARY TO COMPLETE THE WORK.~~

Designer Note:
This note is required on all projects where non-standard signal supports are
included in the plans.~~


442-47
632 SIGNALIZATION, MISC.: UNLASH AND RELASH MESSENGER
WIRE^^

THE CONTRACTOR SHALL REMOVE EXISTING MESSENGER WIRE
LASHING RODS AND REINSTALL THEM AS NECESSARY FOR THE
INSTALLATION OF ANY NEW CABLES ON THE EXISTING INTER-
SECTION SIGNAL SPANS. THE CABLES SHALL ENTER THE
EXISTING STRAIN POLE THROUGH THE POLE CABLE ENTRANCE
FITTING AND USE THE EXISTING CONDUIT SYSTEM TO GET TO
THE CONTROLLER CABINET. THE NEW CABLES SHALL BE
SUPPORTED BY A NEW CABLE SUPPORT ASSEMBLY AT THE TOP
OF THE STRAIN POLE.

THE NEW SIGNAL CABLES SHALL BE BID BY SEPARATE BID ITEMS.

PAYMENT FOR ITEM 632 "SIGNALIZATION MISC.: UNLASH AND
RELASH MESSENGER WIRE" SHALL BE MADE AT THE CONTRACT
UNIT PRICE PER FOOT AND SHALL INCLUDE ALL LABOR,
MATERIALS, CABLE SUPPORT ASSEMBLIES AND EQUIPMENT TO
INSTALL NEW CABLES ON EXISTING SIGNAL SPAN WIRE
INSTALLATIONS.~~

Designer Note:
This note is intended for use on projects where unlashing
and relashing the messenger wire is required in the plans.
Typical use would be for a traffic signal retrofit, where
a new signal head and associated cables are to be added to
the existing span.~~


442-48
809 ADVANCE RADAR DETECTION, AS PER PLAN^^

THIS ITEM OF WORK SHALL CONSIST OF FURNISHING AND
INSTALLING A WAVETRONIX SMARTSENSOR ADVANCE
DETECTION UNIT (MODEL SS-200E). THE DETECTION UNIT
SHALL INCLUDE THE FOLLOWING:

1.  POWER SHALL BE PROVIDED FROM THE TRAFFIC CABINET.

2.  ALL REQUIRED INPUTS CARDS SHALL BE INCLUDED IN THE
    TRAFFIC CABINET AND SHALL BE COMPATIBLE WITH CALTRANS,
    NEMA TS1 AND NEMA TS2 DETECTOR RACKS. THE CARDS
    SHALL PROVIDE TRUE PRESENCE DETECTOR CALLS OR
    CONTACT CLOSURE TO THE TRAFFIC CONTROLLER.

3.  THE UNIT SHALL BE MOUNTED DIRECTLY TO A POLE OR MAST
    ARM, AS RECOMMENDED BY THE MANUFACTURER. CABLE(S)
    SHALL BE PROVIDED AS REQUIRED AND RECOMMENDED BY
    THE MANUFACTURER.

4.  SURGE PROTECTION DEVICES, AS RECOMMENDED BY THE
    MANUFACTURER SHALL BE INCLUDED BOTH AT THE POLE
    WHERE THE UNIT IS LOCATED TO PROTECT THE UNIT AND IN
    THE TRAFFIC CABINET TO PROTECT THE CABINET
    ELECTRONICS.

5.  THE MANUFACTURER'S REPRESENTATIVE SHALL BE ON SITE
    DURING INSTALLATION AND TESTING AND SHALL PROVIDE
    ONSITE TRAINING ON THE SETUP, OPERATION AND
    MAINTENANCE OF THE UNIT.

6.  A SERIAL TO ETHERNET COMMUNICATIONS MODULE AND
    ETHERNET CABLE (MINIMUM 7 FEET).

7.  THE POWER SUPPLY AND COMMUNICATION MODULES SHALL
    BE SECURED TO A SINGLE PANEL THAT CAN BE MOUNTED
    INTERIOR TO THE TRAFFIC CABINET. THE PANEL SHALL
    INCLUDE MODULAR-PLUG STYLE CONNECTIONS FOR UP TO
    FOUR (4) SENSOR CABLES. ADDITIONAL SENSORS MAY BE
    HARD-WIRED TO THE COMMUNICATION MODULES, AS
    NECESSARY.

8.  THE CONTRACTOR SHALL INSTALL THE RADAR DETECTION
    PRIOR TO MILLING/DISABLING EXISTING LOOPS.

9.  THE INSTALLATION SHALL INCLUDE ALL CONTROLLER
    PROGRAMMING FOR COMPLETE INSTALLATION, WHICH
    INCLUDES MODIFICATIONS FOR REMOVAL OF EXISTING
    DETECTION. PAYMENT FOR ITEM 809 ADVANCE RADAR
    DETECTION, AS PER PLAN SHALL BE MADE AT THE CONTRACT
    UNIT PRICE FOR EACH UNIT, COMPLETE AND IN PLACE
    INCLUDING ALL REQUIRED CABINET HARDWARE, MOUNTING
    BRACKETS, CABLES, CONDUIT, CONNECTIONS TESTED AND
    ACCEPTED, AND ANY OTHER NECESSARY HARDWARE TO
    ESTABLISH A FULLY FUNCTIONAL DETECTION SYSTEM.

PAYMENT FOR ITEM 809 ADVANCE RADAR DETECTION, AS PER
PLAN SHALL BE MADE AT THE CONTRACT UNIT PRICE FOR EACH
UNIT, COMPLETE AND IN PLACE INCLUDING ALL REQUIRED
CABINET HARDWARE, MOUNTING BRACKETS, CABLES, CONDUIT,
CONNECTIONS TESTED AND ACCEPTED, AND ANY OTHER
NECESSARY HARDWARE TO ESTABLISH A FULLY FUNCTIONAL
DETECTION SYSTEM.~~

Designer note:
This note is to be used on ODOT-maintained signals only.~~


442-49
809 STOP-LINE RADAR DETECTION, AS PER PLAN^^

THIS ITEM OF WORK SHALL CONSIST OF FURNISHING AND
INSTALLING A WAVETRONIX SMARTSENSOR MATRIX
DETECTION UNIT. THE DETECTION UNIT SHALL INCLUDE
THE FOLLOWING:

1.  POWER SHALL BE PROVIDED FROM THE TRAFFIC CABINET.

2.  ALL REQUIRED INPUTS CARDS SHALL BE INCLUDED IN THE
    TRAFFIC CABINET AND SHALL BE COMPATIBLE WITH CALTRANS,
    NEMA TS1 AND NEMA TS2 DETECTOR RACKS. THE CARDS SHALL
    PROVIDE TRUE PRESENCE DETECTOR CALLS OR CONTACT
    CLOSURE TO THE TRAFFIC CONTROLLER.

3.  THE UNIT SHALL BE MOUNTED DIRECTLY TO A POLE OR MAST
    ARM, AS RECOMMENDED BY THE MANUFACTURER. CABLE(S)
    SHALL BE PROVIDED AS REQUIRED AND RECOMMENDED BY
    THE MANUFACTURER.

4.  SURGE PROTECTION DEVICES, AS RECOMMENDED BY THE
   MANUFACTURER SHALL BE INCLUDED BOTH AT THE POLE
    WHERE THE UNIT IS LOCATED TO PROTECT THE UNIT AND
    IN THE TRAFFIC CABINET TO PROTECT THE CABINET
    ELECTRONICS.

5.  THE MANUFACTURER'S REPRESENTATIVE SHALL BE ON SITE
    DURING INSTALLATION AND TESTING AND SHALL PROVIDE
    ONSITE TRAINING ON THE SETUP, OPERATION AND
    MAINTENANCE OF THE UNIT.

6.  A SERIAL TO ETHERNET COMMUNICATIONS MODULE AND
    ETHERNET CABLE (MINIMUM 7 FEET).

7.  THE POWER SUPPLY AND COMMUNICATION MODULES SHALL
    BE SECURED TO A SINGLE PANEL THAT CAN BE MOUNTED
    INTERIOR TO THE TRAFFIC CABINET. THE PANEL SHALL
    INCLUDE MODULAR-PLUG STYLE CONNECTIONS FOR UP TO
    FOUR (4) SENSOR CABLES. ADDITIONAL SENSORS MAY BE
    HARD-WIRED TO THE COMMUNICATION MODULES, AS
    NECESSARY.

8.  THE CONTRACTOR SHALL INSTALL THE RADAR DETECTION
    PRIOR TO MILLING/DISABLING EXISTING LOOPS.

9.  THE INSTALLATION SHALL INCLUDE ALL CONTROLLER
    PROGRAMMING FOR COMPLETE INSTALLATION, WHICH
    INCLUDES MODIFICATIONS FOR REMOVAL OF EXISTING
    DETECTION.

PAYMENT FOR ITEM 809 STOP-LINE RADAR DETECTION, AS PER
PLAN SHALL BE MADE AT THE CONTRACT UNIT PRICE FOR EACH
UNIT, COMPLETE AND IN PLACE INCLUDING ALL REQUIRED
CABINET HARDWARE, MOUNTING BRACKETS, CABLES, CONDUIT
AND CONNECTIONS TESTED AND ACCEPTED.~~

Designer note:
This note is to be used on ODOT-maintained signals only.~~


442-50
GENERAL ELECTRICAL REQUIREMENTS FOR SOLAR-POWERED
DEVICES^^

RUN REQUIREMENTS OF THIS DEVICE ARE _______ HOURS PER
DAY, 7 DAYS PER WEEK.

UTILIZE ENVIRONMENTALLY-SEALED, HIGH-EFFICIENCY LED
LIGHT SOURCES FOR THIS SOLAR-POWERED APPLICATION.

HOUSE THE SOLAR POWER SUPPLY CONTROLLER AND BATTERY
IN ONE OR TWO STAINLESS STEEL OR ALUMINUM ENCLOSURES
WITH A MINIMUM NEMA 3 OR 3X RATING.

IF THE EXTERIOR SIZE OF THE ENCLOSURE NECESSARY TO MEET
THE REQUIREMENTS BELOW IS LESS THAN 1000 CUBIC INCHES,
A SINGLE POLYMER ENCLOSURE RATED NEMA 4 AND LISTED AS
SUNLIGHT-RESISTANT MAY BE INSTALLED, WITH APPROVAL OF
THE ENGINEER.

SEAL ENCLOSURE CONDUIT ENTRIES TO PREVENT INSECT
AND/OR RODENT ENTRY. PROVIDE METAL ENCLOSURES WITH
AN EXTERIOR OF BARE OR POWDER-COATED ALUMINUM, OR
STAINLESS STEEL.

PROVIDE A LOCKING ENCLOSURE USING EITHER AN INTEGRATED
LOCKING MECHANISM OR A PADLOCK PER C&MS 631.06.

SMALL ENCLOSURES OF 300 CUBIC INCHES OR LESS (EXTERIOR)
MAY BE PROVIDED WITH SECURITY FASTENERS IN LIEU OF A
LOCKING MECHANISM OR PADLOCK.

SEPARATE THE CONTROL ELECTRONICS AND BATTERY, IF
CONTAINED WITHIN A SINGLE ENCLOSURE, TO PREVENT
DAMAGE TO THE CONTROL ELECTRONICS IF THE BATTERY
ENVELOPE IS COMPROMISED.

PROVIDE SEALED GEL-CELL OR AGM (ABSORBED GLASS MAT)
LEAD-ACID BATTERIES FOR ALL INSTALLATIONS WITH
INSTANTANEOUS LOAD REQUIREMENTS OF 4 WATTS OR ABOVE,
REGARDLESS OF DUTY CYCLE.

FOR INSTALLATIONS WITH INSTANTANEOUS LOAD REQUIREMENTS
OF LESS THAN 4 WATTS, RECHARGEABLE NICD, LI-ION, OR NIMH
BATTERIES MAY BE USED INSTEAD OF AGM OR GEL-CELL, IF
APPROVED BY THE ENGINEER.

PROVIDE SIGNED COPIES FROM THE SOLAR PANEL AND/OR
CONTROLLER MANUFACTURER OF ALL CALCULATIONS USED
TO SIZE THE SOLAR PANEL AND BATTERIES.

INCLUDE IN THESE CALCULATIONS THE INSOLATION VALUE USED
AND ITS REFERENCE SOURCE, THE SOLAR PANEL EFFICIENCY,
CHARGER/CONTROLLER EFFICIENCY, INVERTER EFFICIENCY,
PROPOSED LED LAMP AND/OR EQUIPMENT LOAD, AND A FIGURE
REPRESENTING ANTICIPATED MISCELLANEOUS LOSSES.

SHOW CALCULATIONS DOCUMENTING A RESERVE CAPACITY
OF TWO WEEKS OPERATION UNDER CONTINUOUS WORST-CASE
(MINIMUM) INSOLATION FIGURES (USUALLY DECEMBER) FOR
THE PROPOSED GEOGRAPHIC LOCATION, USING A PANEL
ELEVATION ANGLE APPROPRIATE TO THE SITE, AT A SUSTAINED
TEMPERATURE OF 25 DEGREES FAHRENHEIT (-4 DEGREES
CELSIUS).

DELIVER A COPY OF THE CALCULATIONS TO THE ENGINEER AND
ANOTHER COPY TO THE OFFICE OF ROADWAY ENGINEERING
FOR APPROVAL.

PROVIDE DOCUMENTATION SHOWING THAT THE SOLAR PANEL
MANUFACTURER TESTED THE PANEL ACCORDING TO IEC61215
OR EQUIVALENT APPROVED STANDARD.

PROVIDE DOCUMENTATION SHOWING THAT SOLAR PANEL
MOUNTING IS RATED FOR 90 MPH DESIGN WIND AND DESIGNED
TO RESIST VANDALISM.

ENSURE NEC GROUNDING AND BONDING REQUIREMENTS ARE
MET IF VOLTAGES OVER 50V AC OR DC ARE PRESENT.

PROVIDE A TIMER (IF REQUIRED) THAT SATISFIES THE
REQUIREMENTS OF C&MS 731.10 AND IS LISTED ON THE ODOT
QUALIFIED PRODUCTS LIST.

PROVIDE COMPLETE PHOTO-CONTROLLER SPECIFICATIONS,
INCLUDING ON/OFF PHOTOMETRIC SWITCH POINTS (TYPICALLY
GIVEN IN FOOT-CANDLES), IF A PHOTO-CONTROLLER IS UTILIZED.~~

Designer Note:
As noted in Section 440-11, School Speed Limit Sign assemblies and Crossing Sign
assemblies are addressed separately in this manual. Plan Note 442-50 is a generic
template that may be applied to permanent electrical or electronic devices used
on ODOT sign, signal or ITS projects powered by batteries and recharged by solar
panels. This includes, but is not limited to, roadway signs and beacons, equipment
utility/convenience lighting, remote monitoring stations and similar equipment.
In addition to the text above, include in the As-Per-Plan Note a full description
of the construction item and a method of measurement. This template is not intended
for use on devices used for temporary traffic control since the requirements for
those items are typically covered under their respective standards and/or specifications,
and the devices are not retained by ODOT after construction.~~